Installation and Fireplace Setup
+RPH 7HFKQRORJLHV UHFRPHQGV ++7
Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23
WARNING: If the information in these
LQVWUXFWLRQV LV QRW IROORZHG H[DFWO\ D ¿UH
or explosion may result causing property
damage, personal injury, or death.
• DO NOT VWRUH RU XVH JDVROLQH RU RWKHU ÀDP-
PDEOH YDSRUV DQG OLTXLGV LQ WKH YLFLQLW\ RI WKLV
RU DQ\ RWKHU DSSOLDQFH
• DO NOT RYHU¿UH 2YHU¿ULQJ ZLOO YRLG \RXU
warranty.
‡ &RPSO\ ZLWK DOO PLQLPXP FOHDUDQFHV WR FRP-
EXVWLEOHV DV VSHFL¿HG )DLOXUH WR FRPSO\ PD\
FDXVH KRXVH ¿UH
WARNING
HOT SURFACES!
*ODVV DQG RWKHU VXUIDFHV DUH KRW GXULQJ
RSHUDWLRQ $1' FRRO GRZQ
Hot glass will cause burns.
• DO NOT WRXFK JODVV XQWLO LW LV FRROHG
‡ 1(9(5 DOORZ FKLOGUHQ WR WRXFK JODVV
‡ .HHS FKLOGUHQ DZD\
‡ &$5()8//< 683(59,6( FKLOGUHQ LQ VDPH URRP DV
¿UHSODFH
‡ $OHUW FKLOGUHQ DQG DGXOWV WR KD]DUGV RI KLJK WHPSHUDWXUHV
+LJK WHPSHUDWXUHV PD\ LJQLWH FORWKLQJ RU RWKHU ÀDPPDEOH
materials.
‡ .HHS FORWKLQJ IXUQLWXUH GUDSHULHV DQG RWKHU ÀDPPDEOH
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH
SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH 
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EL36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heatilator EL36

  • Page 1 )DFWRU\ 7UDLQHG RU 1), FHUWLILHG SURIHVVLRQDOV WARNING Fire Risk. For use with solid wood fuel only. 2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH  Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 2: Table Of Contents

    ' 6HFXUH 2 VHW5HWXUQ ( ,QVWDOO &HLOLQJ )LUHVWRSV ) ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG G. Roof Penetration + ,QVWDOO &KDVH&KDVH 7RS , 7HUPLQDWLRQ &DS 5HTXLUHPHQWV - ,QVWDOO 7HUPLQDWLRQ &DS Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 3 Comments: )XUWKHU GHVFULSWLRQ RI WKH LVVXHV ZKR LV UHVSRQVLEOH ,QVWDOOHU%XLOGHU2WKHU 7UDGHV HWF DQG FRUUHFWLYH DFWLRQ QHHGHG &RPPHQWV FRPPXQLFDWHG WR SDUW\ UHVSRQVLEOH BBBBBBBBBBBBBBBBBBBBBBBBBB E\ BBBBBBBBBBBBBBBBBBBBBBRQ BBBBBBBBB %XLOGHU*HQ &RQWUDFWRU ,QVWDOOHU 'DWH  ‡ 5HY $ ‡  Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 4: 3Urgxfw 6Shfl¿F

    State of California to cause birth defects or other reproductive harm. For more information go to: www. P65Warnings.ca.gov. Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 5: Getting Started

    4 ft. Decorative facing (1.22 m) off and trim ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 6 1511 1219 opening to any inches 73 7/8 65 1/2 37 1/4 52 1/4 21 1/2 EL42 perpendicular wall. 1219 1422 1876 1664 1327 Figure 2.2 Fireplace Locations Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 7 ‡ /RZHU URRI OLQH LQ FRROHU FOLPDWHV ‡ $YRLG RXWVLGH ZDOO :LQGZDUG /HHZDUG 1RW UHFRPPHQGHG LQ EDVHPHQW GXH WR KLJK QHJDWLYH SUHVVXUH FRQFHUQV WKDW HIIHFW GUDIW Figure 2.3 Recommended Chimney Locations Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 8 5HSRUW WR \RXU GHDOHU DQ\ SDUWV GDPDJHG LQ VKLSPHQW • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety DQG EHQH¿W Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 9: Framing And Clearances

    (191 mm) 7-1/2 in. 7-1/2 in. 14-1/8 in. (191 mm) (191 mm) (359 mm) Model # 23-3/4 11-7/8 EL36 1041 29-3/4 14-7/8 EL42 1067 1194 Figure 3.1 Appliance Dimensions Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 10 0 in. to level of standoffs 1/2 in. (13 mm) to back & sides of appliance 48 in. 1219 mm 0 in. to floor Figure 3.2 Clearances to Combustible Materials Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 11 ,Q FROG FOLPDWHV WKH ZDOOV RI WKH FKDVH VKRXOG EH LQVXODWHG WR WKH OHYHO RI WKH IDOVH FHLOLQJ DV VKRZQ LQ )LJXUH  7KLV ZLOO KHOS UHGXFH KHDW ORVV IURP WKH KRPH DURXQG WKH ¿UHSODFH Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 12 * If interior of chase will be drywalled, add the thickness to this measurement. ** Adjust header height for a raised floor under fireplace. Figure 3.5 Framing the Fireplace Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 13 Raised Platform 2 in. 1 in. (25 mm) min. (51 mm) overlap Floor 2 in. (51 mm) Figure 3.7 Protect the Front of an Elevated Platform Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 14 • Secure flex duct with screws or wire ties. Figure 3.8 Outside Air Installation Figure 3.10 Outside Air Installation with Cold Air Trap Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 15: Chimney And Termination Requirements

    14.5 ft (4.42 m) min. height/single offset-return 39 1/2 in. (1003 mm) 20 ft. (6.1 m) min. height/double offset-return Effective Height 90 ft (27.43 m) max. height Figure 4.1 Chimney Requirements Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 16: Vhwv5Hwxuqv

             3URSHU DVVHPEO\ RI DLUFRROHG FKLPQH\ SDUWV UHVXOW LQ DQ RYHUODS DW FKLPQH\ MRLQWV RI  LQ  PP  ( HFWLYH OHQJWK LV EXLOW LQWR WKLV FKDUW Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 17 In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 4.3 Multiple Chimney Locations Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 18: Chimney Installation

    2 through ceiling or inch clearances. floor Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 19 9HUWLFDO VWUDLJKW UXQV RI FKLPQH\ PXVW EH VXSSRUWHG HYHU\  IW  P  Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 20 ZKHQ WKHUH LV D URRP DERYH ‡ 8VH DQ DWWLF LQVXODWLRQ VKLHOG LI WKH FHLOLQJ LV LQVXODWHG 7KH FHLOLQJ ¿UHVWRS PD\ WKHQ EH DWWDFKHG DERYH RU EHORZ the joists. Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 21 WR HQVXUH SURSHU HQJDJHPHQW EHIRUH LQVWDOOLQJ WKH VXF- FHHGLQJ VHFWLRQV ,I WKH\ KDYH EHHQ FRQQHFWHG FRUUHFW- )LJXUH  ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG ¿UHVWRS EHORZ FHLOLQJ O\ WKH\ ZLOO QRW GLVHQJDJH ZKHQ WHVWHG Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 22 WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. • Caulk all seams to prevent leaks. .018 (26 ga) min. Galvanized Chase Top Figure 5.9 Chase Top Construction Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 23 Figure 5.12 Installing an ST375 Square Termination Cap Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). Figure 5.10 Installing a TR344 Round Termination Cap Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 24 Minimum Height mm) below the top of the chase. 2 in. (51 mm) Chase Top 4-3/4 in. (121 mm) Chase Chimney Pipe Figure 5.15 Installing a DTO134/DTO146/DTS134/DTS146 Cap Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 25: Shrouds

    Shroud Flue 3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. )LJXUH  6KURXG 75 6HULHV FDS ZLWK QR 5DGLDWLRQ 6KLHOG Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 26 Min. Opening Width  [   [  Min. Height Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Figure 6.5 Roofed Style Shroud Dimensions Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 27: Finishing

    2 in. (51 mm) Figure 7.2 Decorative Facing Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 28 4 in. (102 mm) minimum between bottom of fireplace opening and finished surface of hearth extension Model # (/  (/   Figure 7.3 Hearth Extension Dimensions Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 29 6HDO JDSV EHWZHHQ WKH KHDUWK H[WHQVLRQ DQG WKH IURQW RI WKH ¿UHSODFH ZLWK D EHDG RI QRQFRPEXVWLEOH VHDODQW Non-combustible RU JURXW Finishing Materials Figure 7.7 Raised Platform Hearth Extension-Finishing Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 30 Finished 20 in. Min. Figure 7.9 Place Non-combustible Sealant Floor Hearth Extension Micore Noncombustible Material Protective Metal Hearth Strip Figure 7.8 Flush Hearth Extension Side View Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 31 Seal joint with non-combustible NOT cover any air sealant to prevent heat from being openings in the face drawn into the wall cavity. of the fireplace. )LJXUH  0DQWHO 6SHFL¿FDWLRQV Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 32 [305 mm] [305 mm] Fireplace Outside Opening Dimensions Model # EL36 1041 EL42 1067 1194 Figure 7.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening) Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 33: Hduwk

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 8.1 Gas Line Installation Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 34: Reference Materials

    )LHOG &RQVWUXFWHG 6KURXGV 6HH ³:RRGEXUQLQJ 7HUPLQDWLRQ &DS´ Storm Collar &7$% $GDSWHU  0D\ EH XVHG ZLWK WKH IROORZLQJ FDSV &7 6HULHV Attic Shield Kit '7 6HULHV Attic Collar Attic Spacer Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 35 12 in. (305 mm) 10-1/2 in. (267 mm) 24-5/8 in. 31 in. (625 mm) (787 mm) CB876 Chimney Bracket RF371 Roof Flashing TR-TVK - Top Vent Kit CT-3A-B Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 36 TS345/TS345P Square Termination Cap TR342-B Round Telescoping Termination Cap ST375 Square Termination Cap TCT375 Terra Cotta Cap 15-3/4 in. (400 mm) TR344 Round Termination Cap TR342 - Round Telescoping Termination Cap Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 37 DTS134/DTS146 DTO134/DTO146 Decorative Caps DTO134 DTO146 22.7 1168 DTS134 21.18 DTS146 21.18 1168 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 38 42 in. (1067 mm) LDS-BV Decorative Shroud Catalog #   LDS-BV Bifold Glass Doors DM1036, DM1042 See your Heatilator dealer for a complete list of optional components. Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...
  • Page 39  WK 6WUHHW :HVW /DNHYLOOH 01  ZZZKHDWLODWRUFRP 3OHDVH FRQWDFW \RXU +HDWLODWRU GHDOHU ZLWK DQ\ TXHVWLRQV RU FRQFHUQV )RU WKH ORFDWLRQ RI \RXU QHDUHVW +HDWLODWRU GHDOHU SOHDVH YLVLW ZZZKHDWLODWRUFRP Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev S • 11/23...