Installing Non-Combustible Facing Material (Outdoor Side) - Heat & Glo LifeStyle Twilight-II-B Owner's Manual

Indoor/outdoor gas fireplace
Hide thumbs Also See for Twilight-II-B:
Table of Contents

Advertisement

C. Installing Non-combustible Facing
Material (Outdoor Side)
WARNING
Fire Risk.
• Follow these instructions exactly.
• Facing materials must be installed properly to
prevent fi re.
• No materials may be substituted
without authorization by Hearth & Home
Technologies.
• Center and attach two top boards (the two shorter pieces)
to the framing members. See Figure 5.19.
• Use fasteners from fastener packet (in manual bag) in
shaded areas (see Figure 5.19).
• Use regular sheetrock screws in non-shaded areas.
Apply fasteners from
fastener packet in
these areas.
Figure 5.19 Attaching Non-combustible Facing Material
(Outdoor Side Only)
16
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. E • 11/06
• Attach the left and right side pieces to the framing mem-
bers. (See Figure 5.20).
NON-COMBUSTIBLE
FACING MATERIAL
49-5/8 in.
66-1/8 in.
Figure 5.20 Complete Installation of Non-combustible
Facing Material (Outdoor Side)
• Use a wet or dry towel or soft brush to remove dust or
dirt from facing material.
• Apply a non-combustible adhesive to attach tile, stone
or other non-combustible fi nishing materials per manu-
facturer's instructions.

Advertisement