Heat & Glo LifeStyle BAY-40 Owner's Manual

Multi-sided wood burning fireplace
Hide thumbs Also See for BAY-40:
Table of Contents

Advertisement

Quick Links

Models:
BAY-40, PIER-40
Multi-Sided
Wood Burning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
BAY-40 Shown
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo LifeStyle BAY-40

  • Page 1 For use with solid wood fuel or decorative certifi ed or factory-trained professionals, or gas appliance only. technicians supervised by an • DO NOT install unvented gas logs. NFI certifi ed professional. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 2: Congratulations

    ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Note: An arrow ( ) found in the text signifi es change in content. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 3: Table Of Contents

    E. Contact Information G. Fireplace System Requirements H. Inspect Fireplace and Components Framing & Clearances A. Select Fireplace Location B. Clearances C. Sidewalls/Surrounds D. Frame the Fireplace Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 4: Limited Warranty

    Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. 4021-645A 09-01-08 Page 1 of 2 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 5 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. 4021-645A 09-01-08 Page 2 of 2 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 6: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 7: User Guide

    Wood Fuel Section 2.M. Outside Air Control LIFT to OPEN Clear Space Outside Air Hearth Section 2.L. Control PULL to OPEN BAY-40 PIER-40 Figure 2.1 General Operating Parts Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 8: Seasoned Wood

    fi rewood, placed to allow combustion air and fl ames between them. CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 9: Glass Doors

    (152 mm) to front of HEARTH HEARTH fireplace EXTENSION EXTENSION opening (shaded) (shaded) 64 in. 64 in. BAY-40 PIER-40 (1626 mm) (1626 mm) Figure 2.3 Clear Space Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 10: Wood Fuel

    fi relogs that have been evaluated for the application in manufactured fi replaces and refer to fi relog warnings and caution markings on packaging prior to use. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 11: Maintainance And Service

    Top Cover Chimney Slip Section TR11/TR11T TCT1175 ST1175 Round Termination Cap Terra Cotta Square Termination Cap Termination Cap Figure 3.1 Chimney & Termination Cap Cleaning Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 12: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fi replace glass cleaner (consult with your dealer) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 13: Troubleshooting Guide

    Add glass doors to slow down air fl ow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 14: Getting Started

    (Section 11) Hearth extension Outside (Section 11) combustion air Factory-built fireplace (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 15: Design And Installation Considerations

    Tight sealing construction of the structure • Mechanical exhausting devices NOTICE: Hearth & Home Technologies Inc. recommends • Improper location of the chimney the use of direct vent fi replaces in basements. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 16: Locating Fireplace & Chimney

    • Below adjacent structure • Lower roof line • Insulated exterior chase • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Figure 5.2 Recommended Chimney Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 17: Tools And Supplies Needed

    Hearth Extension (required, sold separately) • Outside Air Kit Duct (required for outside air installation, sold separately) • Chimney System (required, sold separately) • Termination Cap (required, sold separately) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 18: Framing & Clearances

    • Mantel Projections HEARTH fireplace EXTENSION EXTENSION • Fireplace Dimensions opening (shaded) (shaded) 64 in. 64 in. BAY-40 (1626 mm) PIER-40 (1626 mm) Figure 6.1 Fireplace Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 19: Clearances

    0 in. to level of standoffs 1/2 in. (13 mm) to back of appliance 48 in. 1219 mm 0 in. to floor Figure 6.2 Air Space Clearances Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 20: Sidewalls/Surrounds

    12 in. max. 12 in. max. (305 mm) (305 mm) 47-1/8 in. (1197 mm) 47-1/8 in. (1197 mm) Header Height Header Height BAY-40 PIER-40 Figure 6.4 Framing the Fireplace Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 21: Installation Of Fireplace

    • Check fi replace opening for square to ensure proper fi t of glass doors. Measure diagonals of fi replace opening to make sure they are equal. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 22 Figure 7.4 Outside Combustion Air Placement Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 23: Install Outside Air Kit

    • Assemble fl exible duct (not supplied) between the door assembly and the inlet tube assembly. Secure it in position with the supplied wire ties. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 24: Chimney Assembly

    Ceiling firestops are required where chimney passes through ceiling or floor Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 25: Chimney Requirements

    20 ft. (5.03 m) min. height/double offset-return (1118 mm) SL1136 34-3/4 90 ft (27.43 m) max. height Effective Height SL1148 46-3/4 1187 * Dimensions refl ect effective height. Figure 8.2 Chimney Requirements Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 26: Using Offsets/Returns

    2511 Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 27: Assemble Chimney Sections

    • Vertical straight runs of chimney must be supported every 35 ft (10.7 m). D. Install Chimney Air Kit Follow instructions provided with this accessory. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 28: Install Ceiling Firestops

    (use 600° F sealant). Catalog # FS538 FS540 Figure 8.5 Installing the Ceiling Firestop Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 29: Install Attic Insulation Shield

    17 in. (432 mm) diameter 6 Tabs bent in 90° Insulation Insulation 13 in. Ceiling Firestop Pipe (330 mm) Figure 8.8 Install Attic Insulation Shield (fi restop below ceiling) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 30: Cut Out Hole In Roof

    Caulk the fl ashing plate and roof junction as well as the vertical seam on the fl ashing. All nail heads must be caulked with a roofi ng sealant. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 31: Chimney Termination Requirements

    Refer to the installation instruc- 6 in. 20 in. (152 mm) min. (508 mm) min. tions supplied with the decorative cap cover. Multiple Chimney Locations Figure 8.10 Multiple Chimney Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 32: Chase Installations

    False Ceiling False Ceiling • Failure to prevent contact between insulation or other Chimney materials and chimney system may cause overheating and fi re. Figure 9.1 Chase Assembly Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 33: Install Fireplace & Chimney

    CAUTION! DO NOT caulk the pipe to the chase top Galvanized Chase Top collar. • Caulk all seams to prevent leaks. • Refer to Figure 9.4. Figure 9.3 Chase Top Construction Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 34: Install Termination Cap

    Chase Top Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST1175 Square Termination Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 35 7 in. (178 mm Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.7 Installing a TCT1175 Terra Cotta Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 36: Shrouds

    737 x 737 584 x 584 Min. Opening Width 26 x 26 20 x 20 660 x 660 508 x 508 Figure 10.2 Open Top Shroud Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 37 34 x 34 34 x 34 864 x 864 864 x 864 Min. Height Above Radiation Shield Min. Opening Width Min. Opening Height Figure 10.4 Roofed Style Shroud Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 38: Finishing

    Common Brick 0.20 5-1/8 in. Ceramic Tile 12.50 0.08 12-1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14-5/8 in. - 20-3/8 in. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 39 Protective insulation Metal Hearth (see Table 11.2) Strip 2 in. (51 mm) required Floor constructed of wood or other combustible material Figure 11.1 Hearth Extension Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 40: Finishing Material

    2 in. (51 mm) Figure 11.3 Decorative Facing Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 41: Combustible Mantel

    [1016 mm] [1016 mm] BRICK FRONT FRONT 12 in. 12 in. [305 mm] [305 mm] Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 42: Accessories

    Repack beyond 4 in. (102 mm) Insulation from fireplace side. Knockout 4 in. (102 mm) Figure 12.1 Gas Line Installation Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 43: Reference Materials

    44" " 8¾" 3" 40" 8¼" OUTSIDE AIR COVER PLATE KNOCKOUT 9½" 12" " 24" 7" END VIEW - BAY-40 BOTTOM VIEW END VIEW - PIER-40 BAY-40 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 44: Optional Components

    66 in. (1676 mm) 20 in. (508 mm) HX4 Hearth Extension 1/2 in. (13 mm) See your Heat & Glo dealer for a complete listing of optional components. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 45: Chimney Components

    (527 mm) (279 mm) (133 mm) 4 in. (102 mm) 13 in. Outside Diameter (330 mm) 13 in. (330 mm) SL11 Vent Stabilizer CAK5A Chimney Air Kit Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 46 28 in. (330 mm) 39-7/8 in. (711 mm) (1013 mm) CB576 Chimney Joint Band RF571 Roof Flashing 10 3/4 in. 26 in. TR-TVK TR Top Vent Kit CT-11A Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 47 (508 mm) 17 in. (432 mm) 9-3/8 in. (238 mm) LDS-BV Decorative Shroud 9-1/4 in. Catalog # (235 mm) 12-1/2 15-1/2 LDS-BV TCT1175 - Terra Cotta Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 48: Service Parts

    D. Service Parts Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 49 D. Service Parts (continued) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 50 This page intentionally left blank. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 51 This page intentionally left blank. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...
  • Page 52: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev V • 11/08...

This manual is also suitable for:

Pier-40

Table of Contents