Seal fl ashing to exterior of building using hightemp caulk.
Attach to building using holes provided on the top of the
left and right sides of outdoor fl ashing (see Figure 5.15).
Apply housewrap or building paper
For placement of combustible housewrap or building pa-
per and non-combustible sheathing for the outside wall
see Figure 5.16.
WALL STUD
FIREPLACE
HEADER
HOUSEWRAP
INSULATION
FLASHING
HEADER
INSULATED
FRAMING
STANDOFF
Figure 5.16
SHEATHING,
COMBUSTIBLE
**
HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.
*
NON-COMBUSTIBLE
SHEATHING
12 in.
16-5/16 in.
TOP OF
FIREPLACE
TL-TRIM KIT
TOP HOOD
APPLIANCE
HOOD
Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. E • 11/06
* NOTE: All fi nishing materials on top of exterior sheathing
must be non-combustible for a minimum of 12 inches
above and on both sides of the exterior face of the
appliance. This non-combustible fi nishing material can
be up to a maximum of 6 inches thick (6 inches maximum
horizontal overhang) to allow for brick and stone alcoves
(see Figure 8.5).
** NOTE: Combustible house wrap or building paper
MUST NOT extend over the outside of non-combustible
sheathing, and MAY extend over the fl ashing behind
non-combustible sheathing. Use high temp caulk to seal
between combustible sheathing house wrap and non-
combustible sheathing.
Once the appliance is in place use enough silicone caulk
to make a water tight seal between outdoor surround and
exterior sheathing.
Face the perimeter of the appliance with non-combustible
sheathing over shroud fl anges and fl ashing. See Figure
5.17 for non-combustible zone.
NON-COMBUSTIBLE
ZONE
12 in.
Figure 5.17 Non-combustible Zone (Exterior)
WARNING
Risk of Fire
• Non-combustible clearances
must be maintained.
• Sheetrock, wood or other
combustibles must NOT be used as sheathing or
facing in the non-combustible zone.
• See Sections 3 and 8 for proper clearances.
• See Section 1 for combustible /non-combustible
defi nitions.
12 in.
12 in.
15