HANGING INSTRUCTIONS
1. Assemble according to the illustration and tighten all
eyebolts securely. See Fig. 3.
FIG. 3
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
2. Be sure heater is securely fastened and is hanging
level. (Check crosswise and lengthwise.)
3. See Fig. 4 for typical indoor installation. In any animal
confinement building, consideration must be given to
making sure the heater is located away from the
livestock so that livestock cannot knock the heater,
tear it loose from its mounting, or damage the heater
or its gas supply line in any way. Make sure you
observe and obey minimum clearance distances to
combustible materials as stated in the specification
section of this owner's manual and on the heater
itself.
SEDIMENT TRAP ASSEMBLY
Assemble the tee, nipples and cap together and tighten
securely. See Fig. 5. The sediment trap assembly must
always be mounted in a vertical position. Make sure pipe
thread compound that is resistant to both L.P. gas and
natural gas is used in making all connections. Check all
connections for gas leaks using approved gas leak
detectors.
9
FIG. 4
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.
LINE NO SMALLER THAN VENT OPENING.
CHAIN
VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS
CASE TOP
FIG. 5
REGULATOR VENT MUST
POINT DOWN
OPTIONAL INDOOR
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
MOUNTING LOCATION
GAS HOSE
GAS HOSE
THERMOSTAT
CORD
HEATER
HEATER
AIR DIVERTER
YOKE
1 FT. MIN.
1 FT.
NIPPLE
TO GAS CONTROL
VALVE INLET
MANUAL SHUT OFF VALVE CAN BE
MANUAL SHUT-OFF VALVE
INSTALLED BEFORE THE REGULATOR
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
UNDER THE EAVE OF THE BUILDING,
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR INSIDE
OR AFTER THE REGULATOR
THE BUILDING.
INSIDE THE BUILDING.
PIPE THROUGH WALL
BLACK PIPE
THROUGH WALL
VENT LINE
VENT LINE
WALL OUTLET
WALL OUTLET
POWER CORD
POWER CORD
SEDIMENT TRAP
SEDIMENT
1 FT.
TRAP
1 FT.
MIN.
HOSE ADAPTER
TEE
NIPPLE
CAP