Interconnection For Variable Heat - L.B. White GUARDIAN Smart Sense AD250 Owner's Manual And Instructions

Agricultural animal confinement building heaters with smart sense automatic variable rate heat for use with smartbox controller
Hide thumbs Also See for GUARDIAN Smart Sense AD250:
Table of Contents

Advertisement

INTERCONNECTION FOR VARIABLE HEAT

Complete installation and operating instructions are
provided separately with the SmartBox
Use customer supplied wire nuts and other
appropriate electrical terminals when interconnecting
the SmartBox
Refer to labels on wires for connections.
Ensure proper electrical wiring gauge for main power
supply from SmartBox
Use 18 gauge electrical wiring for supply of DC volts
from SmartBox
control on heater.
A. 115 Volt main power wiring from SmartBox
heaters.
Connect leads as shown in Fig.7 to heating Zones 1
and 2.
FIG. 7
B. Wiring from SmartBox
variable rate gas control valve
a. Connect Smart Sense™ gas control valve wiring for
Zones 1 and 2 at SmartBox
Fig.8.
FIG. 8
12
.
to the heater.
to heater.
to Smart Sense
variable rate gas
to the heater's Smart Sense
leads as shown in
b. Route the wiring from these leads through the gas
inlet hole at the heater's case. See Fig.9.
c. Attach 1/4 in. insulated female terminals to these
wires and connect to either terminal on the valve.
See Fig. 9.
FIG. 9
CONNECT WIRING TO TERMINALS
( NOT POLARITY SENSITIVE)
to
d. See Fig.10 for typical connections. Each
SmartBox
FIG. 10
ZONE 1 OR ZONE 2 WIRING FROM
SmartBox™
TO
VARIABLE RATE GAS CONTROL VALVE
HEATER 1
GAS VALVE
ROUTE WIRING
THROUGH HOLE
zone can control two heaters.
Smart Sense™
HEATER 2
GAS VALVE

Hide quick links: