Heater Specifications - L.B. White GUARDIAN Smart Sense AD250 Owner's Manual And Instructions

Agricultural animal confinement building heaters with smart sense automatic variable rate heat for use with smartbox controller
Hide thumbs Also See for GUARDIAN Smart Sense AD250:
Table of Contents

Advertisement

Heater Specifications

SPECIFICATIONS
Type Fuel
Maximum Input (BTUH)
Minimum Input (BTUH)
Ventilation Air Required
to Support Combustion (CFM)
Inlet Gas Supply
Pressure Acceptable at the
Inlet of the Heater for
Purpose of Input
Adjustment (in. W.C.)
Burner Manifold Pressure
(in.W.C.)
Fuel Consumption Per
Hour
Motor Characteristics
Electrical Supply
(Volts/Hz/Phase)
Amp Draw
(Starting Amps
Includes Igniter)
Dimensions (Inches)
L x W x H
Minimum Safe
Distances From
Nearest
Combustible
Materials
Net Weight (lbs.)
Shipping Weight (lbs.)
4
MAX.
MIN.
MAX.
MIN.
MAX.
MIN.
STARTING
CONTINUOUS
OPERATION
TOP
SIDES
BACK
BLOWER
OUTLET
GAS
SUPPLY
Model
AD250
Propane
Gas
250,000
65,000
1,050
13.5
11.0
10.0
0.5
11.58 lbs.
3.01 lbs.
Ball Bearing
1/3 H.P.
1100 RPM
115/60/1
7.3
4.5
30
18
x
3/4
1/4
1 ft. (.3 m)
1 ft. (.3 m)
1 ft. (.3 m)
6 ft. (1.83 m)
6 ft. (1.83 m)
116
126
Natural
Gas
8.5
7.5
250 cu.ft
65 cu.ft
28
x
1/4
N/A