In planning the installation for the fireplace, it is necessary to
determine where the unit is to be installed and whether optional
accessories are desired. Gas supply piping should also be planned
at this time.
The fireplace can be mounted on any of these surfaces:
1. A flat hard combustible or non-combustible surface.
2. A raised platform of non-combustible material.
3. Four (4) corners of the fireplace so contact is made on all four
perimeter edges on the bottom of the unit.
(Example: Four (4) concrete masonry blocks.)
If the fireplace is installed directly on carpeting, tile or other
combustible material other than wood flooring, it should be installed
on a metal or wood panel extending the full width and depth of the
unit.
At this point, you should have decided what components to include
in your installation, and where the fireplace is to be located. If this
has not been done, stop and consult your dealer for assistance
with this planning.
This fireplace is intended for installation on an outdoor patio or
in your yard. This fireplace shall be used only outdoors in a well
ventilated space and shall NOT be used in a building, garage, or
other enclosed area.
It is recommended that this fireplace be installed in a "sheltered"
area. Direct wind will cause an erratic flame and possible pilot or
main burner outage. This erratic flame could also lead to excessive
black soot. These issues are nuisance issues rather than a safety
issues.
Typical installation may include covered patio, screened porch,
gazebo or an outside wall of a house.
Minimum porch area – 96 square feet
Minimum ceiling height – 92 inches
This fireplace is not been tested nor approved to have a television
or other electrical appliance installed above it.
Page 10

pLANNING INSTALLATION

WARNING
Outdoor Fireplace Enclosure Requirements
Do not install appliance until all necessary provisions are made
for combustion and ventilation air. Consult the written instructions
provided with the appliance for information concerning combustion
and ventilation air. In the absence of instructions, refer to the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion
and Ventilation, or applicable local codes.
NOTICE: This fireplace is NoT equipped with an oDS pilot.
Installation must conform with one of the following conditions:
With walls on all sides, but with no overhead cover;
Within a partial enclosure which includes an overhead cover
and no more than two side walls. These side walls may be
parallel, as in a breezeway or at right angles to each side; or
Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery of the enclosures is permanently open.
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Clearances
The front of the fireplace may have 0" clearance as far back as 1/2"
where studs are to be placed.
WARNING
Figure 5
Figure 6
32274-0-0713