Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with this fireplace.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of an unvented
room heater.
*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN
BE DANGEROUS.
Improper installation or use of the appliance can cause se-
rious injury or death from fire, burns, explosion or carbon
monoxide poisoning.
This series is design certified in accordance with American National
Standard Z21.97.1/CSA 2.41 by the Underwriters Laboratories as
an Outdoor Gas Fireplace and should be installed according to
these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
750 Millivolt System
When you ignite the pilot, the thermocouple produces millivolts
(electrical current) which energizes the magnet in the gas valve.
After 30 seconds to 1 minute time period you can release the gas
control knob and the pilot will stay ON. Allow your pilot flame to
operate an additional one (1) to two (2) minutes before you turn the
gas control knob from the PILOT position to the ON position. This
time period allows the millivolts (electrical energy) to build-up to a
sufficient level allowing the gas control to operate properly.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Moisture Resistance
This outdoor fireplace will shed moderate amounts of water, but is
not waterproof. Water and condensing water vapor may enter the
chase under certain conditions.
The fireplace will not perform as an exterior wall. Moisture penetration
must be considered for construction that places the fireplace in
structure walls or on moisture sensitive surfaces.
When installed on exterior walls: Empire Comfort Systems
recommends the fireplace chase be constructed outside the
structure's weather envelope. Where the platform meets the wall, use
a flashing detail similar to that required for attached decks. Chase
platforms, including hearths should slope away from the structure
at 1/4 in per foot. The fireplace can be shimmed level.
When installed on surfaces where water may collect or cause
damage: Empire Comfort Systems recommends a slope of 1/8 in
to 1/4 in per foot towards the drain port suggested. The fireplace
can be shimmed level.
Hearths should slope away from the front of the fireplace and chase
32274-0-0713

INTRODUCTION

WARNING
at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of
any combustible hearth materials used for moisture management.
When purchasing a firebox or fireplace we recommend you also
buy a weather cover or glass door accessory to protect the unit
from moisture. Never install a burner where moisture cannot drain
off easily. We recommend a weather barrier - such as a cover or
bifold glass doors - to protect the burner from moisture.
Screened porch Installation
The fireplace may be installed safely and is design certified by UL
to be installed in a screen porch with the following guidelines.
Minimum Porch Area
Minimum Ceiling Height
(See Page 10)
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Solid-fuels shall not be burned in a masonry or UL 127 factory-
built fireplace in which an unvented room heater is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsible for
(a) the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 1430
Broadway, New York, N.Y. 10018.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating value.
Contact the manufacturer or your gas company before changing
spud/orifice size.
WARNING: This appliance is equipped for (natural gas or propane)
gas. Field conversion is not permitted.
96 sq. feet (9 sq m)
92" (234 cm)
Page 5