Gas Line Connection - Empire Comfort Systems OLP36FP72SN-2 Owner's Manual

Outdoor gas fireplace
Table of Contents

Advertisement

FIREpLACE FRAMING AND INSTALLATION
Alternate Framing and Installation Method
1. Install flanges on side of fireplace as shown using holes on
side of firebox. See Figure 9. The middle pair of holes if for
the 1/2 inch non-combustible board provided with the unit.
2.
Connect the side framing studs to the top stud as shown in
Figure 13. The channel of the studs should face inward.
The fireplace is designed to accept a 3/8-inch gas line for an
approved ventless gas logset. Have the line installed by a qualified
service person in accordance with all building codes. Consult local
building codes to properly size the gas supply line leading to the 3/8-
inch hook-up at the unit. The state of Massachusetts requires that
a flexible appliance connector cannot exceed three feet in length.
A flex-line and shut-off valve have been provided. The gas shut-off
valve must be located outside of the unit in an accessible area.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all LP fireplaces to reduce the
supply tank pressure to a maximum of 14" w.c. This is in addition
to the regulator fitted to the log set.
WARNING: CONNECTION DIRECTLY TO AN UNREGULATED
L.P. TANK CAN CAUSE EXPLOSION.
Install only a ANSI Z21.97.1/CSA 2.41 ventless log set into this
fireplace.
32274-0-0713
Figure 12

GAS LINE CONNECTION

3. Connect the framing studs to the flanges using four #10 pan-
head screws.
Note:
If using a drain tray, the bottom of the side framing studs
will be approximately 1" from the bottom of the firebox.
4. Locate the middle bracket. Loosen the screw in the middle
top of the fireplace. Slide the bracket under the screw as
shown in Figure 11. Tighten the hex-head screws on the
fireplace secure a pan-head screw through the middle
bracket and into the top stud.
5.
Locate the two non-combustible boards and place them
above the fireplace as shown in Figure 12. Attach the
non-combustible board to the studs with six 10-16 flathead
screws.
6. Secure the non-combustible board to the middle bracket
using two 10-16 flathead screws as shown in Figure 12.
7. Move the fireplace into position. Connect the gas line to the
unit and check for leaks with a soapy water solution.
Note: Ensure that the gas shut-off valve is accessible.
8. Secure fireplace to framing or floor.
Figure 13
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents