In planning the installation for the firebox, it is necessary to determine
where the unit is to be installed and whether optional accessories
are desired. Gas supply piping should also be planned at this time.
The firebox can be mounted on any of these surfaces:
1. A flat non-combustible surface.
2. A raised platform non-combustible material.
3. Four (4) corners of the firebox so contact is made on all four
perimeter edges on the bottom of the unit.
(Example: Four (4) concrete masonry blocks.)
If the firebox is installed directly on carpeting, tile or other combustible
material other than wood flooring, it should be installed on a metal
or wood panel extending the full width and depth of the unit.
At this point, you should have decided what components to include
in your installation, and where the firebox is to be located. If this
has not been done, stop and consult your dealer for assistance
with this planning.
This firebox is intended for installation on an outdoor patio or
in your yard. This firebox shall be used only outdoors in a well
ventilated space and shall NOT be used in a building, garage, or
other enclosed area.
It is recommended that this firebox be installed in a "sheltered" area.
Direct wind will cause an erratic flame and possible pilot or main
burner outage. This erratic flame could also lead to excessive black
soot. These issues are nuisance issues rather than a safety issues.
Typical installation may include covered patio, screened porch,
gazebo or an outside wall of a house.
Minimum porch area – 96 square feet
Minimum ceiling height – 82 inches
Minimum of two walls to be open or screened to the following
guidelines.
Minimum screen area – 64 square feet
Minimum top of screen height (side walls) – 70 inches
Page 8

PLANNING INSTALLATION

Installing the Hood
A stainless steel hood is furnished with each outdoor firebox. The
hood MUST be installed before the firebox is used. Failure to do
so may create a possible fire hazard.
Finishing
Hearth extensions are recommended, not a requirement for these
gas fireboxs.
Cleaning Instructions
This appliance is built using mostly high-grade stainless steel to
resist rust-through. In outdoor applications, all stainless steel will
develop a dull patina and, depending on the local environment
and on the materials used in the installation, may develop some
surface oxidation (rust). This does not affect the performance of
the firebox, and does not require any action to correct. If you pre-
fer keeping your firebox front looking factory-fresh, clean it as re-
quired with stainless steel cleaner.
When installation application includes highly acidic applications
such as mortar or stone etching, do not remove the protective PVC
film from the stainless steel until after this application is complete.
Once the film has been removed we recommend that the appli-
ance be cleaned with a stainless steel cleaner immediately.