Electrical Specifications
Caution:
permanent damage to the MatchPort AR. Exposure to Absolute Maximum
Rating conditions for extended periods may affect the MatchPort AR's
reliability.
Parameter
Supply Voltage
CP Voltage
Ethernet ETX+, ETX-, ERX+, ERX-
Voltage
Operating Temperature
Storage Temperature
Parameter
Supply Voltage
Supply Voltage Ripples
Supply Current
Supply Current (In-Rush)
Supply Reset Threshold
CP Pull-ups, except CP5
CP5 Pull-up
CP, RX, CTS, BOOTP_EN#
Input Low Voltage
CP, RX, CTS, BOOTP_EN#
Input High Voltage
CP, TX, RTS Output Low
Voltage
(I
= 4 mA)
OL
CP, TX, RTS Output High
Voltage
(I
= -4 mA)
OH
E_LINKLED, E_ACTLED
Current Drive (sink)
Note:
Do not connect a pull-down resistor on E_LINKLED and E_ACTLED.
MatchPort AR™ Integration Guide
Figure 2-8. BOOTP_EN# APPLICATION CIRCUIT
Stressing the device above the rating listed in this table may cause
Table 2-3. Absolute Maximum Ratings
Table 2-4. Recommended Operating Conditions
Symbol
V
CC
V
CC_PP
I
CC
V
RST
R
PU
R
PU
V
CP_IL
V
CP_IH
V
CP_OL
V
CP_OH
I
LED
2:Description and Specifications
Symbol
Min
V
0
CC
V
-0.3
CP
V
0
ETH
-40
-40
Min
Typical
Max
3.15
3.3
3.46
2
200
9/10
2.85
2.93
3.00
100
20
0.8
2
0.4
V
-
CC
0.4
12
Max
Units
3.6
Vdc
V
+0.05
Vdc
CC
V
+0.3
Vdc
CC
o
85
C
o
85
C
Units
Vdc
%
mA
A/microsec
Vdc
Kohm
Kohm
Vdc
Vdc
Vdc
Vdc
mA (see note
below)
15