Kohler Engine Parts Call K&T 606-678-9623 or 606-561-4983
Test 3 – Check for timing advance
Figure 8-8.
1. Make a line near the edge of the flywheel screen
with a marking pen or narrow tape.
2. Connect an automotive timing light to cylinder that
had good spark.
Figure 8-9.
3. Run the engine at idle and use the timing light
beam to locate the line on the screen. Draw a line
on the blower housing adjacent to the line on the
screen. Accelerate to full throttle and watch for
movement of the line on the screen relative to the
line on the blower housing. If both cylinders had
good spark, repeat the test on the other cylinder.
a. If the line on the screen moved away from
the line on the blower housing during
acceleration, the SAM is working properly. If
it didn't move away, go to Test 5.
Electrical System and Components
Test 4 – Test the ignition modules and connections
1. Remove the blower housing from the engine.
2. Disconnect the leads from the ignition module(s)
3. Remove one of the mounting screws from each of
4. Refer to the chart on page 8.10 to identify which
www.mymowerparts.com
b. If you were able to check timing on both
cylinders, the lines you made on the blower
housing should be 90° apart. If they're not,
go to Test 4.
Inspect the wiring for any damage, cuts, bad
crimps, loose terminals or broken wires.
and clean all of the terminals (male and female)
with aerosol electrical contact cleaner to remove
any old dielectric compound, dark residue, dirt, or
contamination. Disconnect the spark plug leads
from the spark plugs.
the ignition modules. If the mounting screws are
black, remove them both and discard. Replace
them with part number M-561025-S. Look in the
mounting hole with a flashlight and use a small
round wire brush to remove any loose rust from
the laminations inside the mounting hole.
ignition module(s) you have. If they are the smaller
style, check the vendor part number on the face.
All modules with vendor part numbers MA-2,
MA-2A, or MA-2B (Kohler Part No. 24 584 03)
should be replaced with 24 584 11 or 24 584 15-S.
For small modules with vendor numbers MA-2C or
MA-2D (Kohler Part No. 24 584 11), or the larger
style modules (24 584 15-S and 24 584 36-S), use
a digital ohmmeter to check the resistance values
and compare them to the table following. When
testing resistance to the laminations, touch the
probe to the laminations inside the screw hole, as
some laminations have a rust preventative coating
on the surface which could alter the resistance
reading.
a. If all of the resistance values are within the
ranges specified in the table, go to step 5.
b. If any of the resistance values are not within
the ranges specified in the table,
module is faulty and must be replaced.
#
NOTE: The resistance values apply only to
modules that have been on a running
engine. New service modules may have
higher resistance until they have been
run.