INSTALLATION

Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
CHASSIS INSTALLATION
Units are shipped without a sleeve. In applications where unit is a replacement, it is recommended that a
GREE or Carrier sleeve be used.
These units can retrofit General Electric, Amana, Trane, and Friedrich sleeves/grilles (be sure outdoor
grille is installed on the sleeve). See Table 3 for details.
For any sleeve retrofit applications, be sure that the foam seals (factory- -installed on the tube sheets)
provide a good seal between the grille and outdoor coil tube sheets. These foam seals provide a barrier to
separate outdoor coil leaving air from mixing with the outdoor incoming air (known as air recirculation).
CAUTION
!
UNIT DAMAGE AND/OR OPERATION HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
For retrofit applications, foam seals on outdoor coil tube
sheets must make a seal between the coil and the grille or
loss of performance and premature damage to the major
components can result.
WIRE SCREEN
DISCHARGE
GRILLE
INDOOR-AIR
INLET
FILTERS
FRONT
PANEL
Manufacturer
General Electric
Amana
Trane
Friedrich
* FR---SLEEVE ---EXT accessory is required for retrofit into Friedrich
(T ---Series) wall sleeves.
OUTDOOR
ORIFICE
INDOOR
COIL
Fig. 4 – Unit Components
5
Table 3—Retrofit Wall Sleeves
Wall Sleeve Part Number
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T ---Series Metal 11
Sleeve*
Standard Depth Wall Sleeve
3/4
16 X 42 X 13
---in. PXWS
COIL TUBE
SHEETS
ACCESSORY
BASEPAN
WALL
SLEEVE
1/2
---in. Deep Wall
ACCESSORY
OUTDOOR
GRILLE