  • Page 1 Model No. SG-PAC-10E5 Reference No. KY-100E5 10,000 BTU Portable Air Conditioner Operating Instructions...
  • Page 2: Important Instructions

    Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner.
  • Page 3: Package Contents

    These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. • If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly. Model Number Reference Number...
  • Page 4: Lcdi Power Cord And Plug

    If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Powered by Gree Customer Service for trou- bleshooting recommendations.
  • Page 5: Product Diagram

    PRODUCT DIAGRAM Control Panel Louver Guides Louvers Casters Remote Control Holder Power Cord Filters Upper Air Intake Air Exhaust Vent Lower Air Intake...
  • Page 6: Assembly And Installation

    INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be installed. When the unit is operating in fan mode, the window kit and exhaust hose do not need to be installed .
  • Page 7: Single Hose Window Kit Installation

    SINGLE HOSE WINDOW KIT INSTALLATION This installation is OK The is a poor installation 22” When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary, use single 90° angles like the pictures above.
  • Page 8: Control Panel, Display, & Operating Instructions

    Dehumidifier, and Fan only mode. Each press of the MODE button will light up a different icon on the control panel. The exhaust hose and window kit must be installed when the unit is in Air Conditioner or Dehumidifier mode. When using the unit as a fan, it is not necessary to keep the exhaust hose and window kit connected to the unit.
  • Page 9: Remote Control Operating Instructions

    SPEED label. 4) Temperature Setting - When the unit is in Air Conditioner mode you can select your desired temperature. Press the TEMP SELECT buttons (+ or -) to select your desired temperature setting. The temperature on the LCD display on the remote control will increase or decrease accordingly.
  • Page 10 REMOTE CONTROL OPERATING INSTRUCTIONS (Cont.) 5) Auto-on Timer: When the air conditioner is off, it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Timer, press the TIMER button on the unit or remote control. Each touch of the +/- buttons on the remote will change the timer setting in 30 minute increments (.5 hours).
  • Page 11: Draining Collected Water

    DRAINING COLLECTED WATER When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is unable to be evaporated is placed in a small bank up water tank in- side the unit.
  • Page 12: Clean/Replace Filter

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
  • Page 13: Troubleshooting

    The Air Conditioner displays the Timer hours but does not work The Remote Control is not working POSSIBLE CAUSES The air conditioner is unplugged or not connected well. The fuse is blown/circuit breaker is tripped. Power Failure The current interrupter device is tripped.
  • Page 14 TROUBLESHOOTING (CONT.) PROBLEM The LCD Display is showing “E5” The LCD Display is showing “H8” POSSIBLE CAUSES Low Voltage Protection The backup water tank is full SOLUTIONS • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service.
  • Page 15: This Warranty Does Not Cover

    One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.