Summary of Contents for Soleus Air GM-WAC-15ESE-C

  • Page 1 Models GM-WAC-15ESE-C GM-WAC-18ESE-C Electronic Window A/C Operating Instructions...
  • Page 3: Important Safety Instructions

    Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner.
  • Page 4: Electrical Requirements

    • A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree. • The power supply cord contains new user serviceable parts.
  • Page 5: Parts List

    PARTS LIST WINDOW SASH SEAL SAFETY LOCK AND 3/4" ROUND-HEAD SCREW TOP ANGLE FOAM GASKET FRAME ASSEMBLY (LEFT) SIDE RETAINER SEAL-BOTTOM RAIL TO UNIT 1/2" LONG SCREWS AND FRAME TOOLS NEEDED LOCKNUTS ASSEMBLY (RIGHT) Large Flathead Screwdriver WINDOW SUPPORT LOCKNUT Tape Measurer BRACKET 3/4"...
  • Page 6: Specifications

    SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model GM-WAC-15ESE-C GM-WAC-18ESE-C...
  • Page 7: Window Preparation

    INSTALLATION & ASSEMBLY INSTRUCTIONS Window Preparation Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit.
  • Page 8: Remove Chassis

    INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 1. Pull down the front panel and remove the filter (FIG. 1 below) 2. Lift the front panel upwards to remove and place to the side. FIG. 1 FIG. 1 FIG. 2 3.
  • Page 9 INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 1. Pull down the front panel and remove the filter (FIG. 1 below) 2. Lift the front panel upwards to remove and place to the side. FIG. 2 FIG. 1 3. Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air con- ditioner (FIG.
  • Page 10 INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING REMOVE CHASSIS 6. Remove the screws from the right side of the cabinet (FIG 7). FIG. 7 7. Hold the cabinet while pulling on the base handle to carefully remove the unit. Do not pull or lift near the top of the unit (FIG 8).
  • Page 11: Top View

    ASSEMBLY & INSTALLATION (CONT.) Top Angle Rail and Side Bracket Installation FIG. 9 1. Place the air conditioner on a hard flat surface. 2. Locate the foam gasket and top angle rail 3. Attach the foam gasket to the top angle rail 4.
  • Page 12: Install Support Brackets

    Install Support Brackets Extend the Accordion Panels 1. Hold each support bracket flush against the outside of 1. Carefully raise the window to expose the accordion the window sill. Tighten each bracket to the bottom of panel and panel frame. Loosen the locking screws so the cabinet as shown below.
  • Page 13: Thru-The-Wall Installation

    ASSEMBLY & INSTALLATION (CONT.) Installing the Chassis into the Cabinet THRU-THE-WALL INSTALLATION 1. Team lift (two people) the air conditioner chassis and carefully slide it into the cabinet. Let the front of the air NOTE: Consult local building codes prior to installation conditioner hang out approximately 6”.
  • Page 14 ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Carefully measure and cut an opening with the following NOTE: If wall thickness is 8-1/2” or more, add aluminum dimensions depending on your model (FIG. 1 & 2). flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall.
  • Page 15: Masonry Construction

    ASSEMBLY & INSTALLATION - THRU-THE-WALL (CONT.) Refer to the SUPPORT BRACKET ASSEMBLY in the MASONRY CONSTRUCTION WINDOW MOUNTING section to assemble the support brackets. A wooden strip nailed to the outside wall should 1. Cut or build a wall opening in the masonry wall similar be used in conjunction with the angled sill support brack- to the frame construction (refer to the THRU-THE- ets.
  • Page 16: Using Your Air Conditioner

    USING YOUR AIR CONDITIONER 3. Temperature Set: Use these buttons on the con- trol panel and remote to increase or decrease the Electronic Control Panel & Remote Control Set Temperature (the desired room temperature) in cooling,energy saver and dry mode. The SET NOTE: This display always shows the room temperature in Fan light will light up when setting the temperature Mode except when setting the Set temperature or the Timer.
  • Page 17: Operating Your Air Conditioner

    OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 5. FAN - Press the FAN button to turn change the FAN options. You can choose between four speeds and auto mode. The fourth fan option is only available in cooling and energy saver modes. 6.
  • Page 18 OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 9. LOCK/UNLOCK- Press the “+” and “—” buttons simultaneously to lock and unlock the remote control. When the remote is locked, none of the functions or setting can be changed using the remote. 10. F° or C° - To switch between the F° or C° settings, press the MODE and “—” buttons a the same time. 11.
  • Page 19 USING YOUR AIR CONDITIONER (Cont.) • Freezing Conditions: This is a cooling only air • Fan Only Mode: Use Fan Only mode at Low, conditioner. It is not designed for freezing outdoor Med, or High fan speed to provide air circulation conditions.
  • Page 20: Care And Cleaning

    Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. Unplug the air conditioner to prevent shock or • a fire hazard. The cabinet and front panel of the air conditioner may be dusted with an oil- Air Filter Cleaning The air filter should be checked at least once...
  • Page 21: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The air conditioner is unplugged • Make sure the air conditioner is The Air Conditioner will not start plug is pushed completely into the outlet • Check the house fuse/circuit The fuse is blown/circuit breaker is breaker box and replace the fuse tripped.
  • Page 22 TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS Hot and Humid weather. • This is normal Water is dripping outside The air conditioner is not correctly • For proper water drainage, make Water is dripping inside the room tilted outside. sure the air conditioner is slightly tilted downward from the front of the unit to the rear.
  • Page 23: Warranty

    Warranty Soleus International Inc. warrants the accompanying Soleus Air Air Conditioner to be free of defects in mate- rial and workmanship for the applications specified in its operation instruction for the period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance.
  • Page 24 66129908033...