How To Connect - Soleus Air SG-PTAC-09HPDA Owner's Manual

Packaged terminal air conditioner 9,000-15,000 btu/hr
Table of Contents

Advertisement

HOW TO CONNECT

IMPORTANT: Please read following electrical safety data carefully.
WARNING
!
ELECTRICAL SHOCK AND/OR UNIT OPERATION AND DAMAGE HAZARD
Failure to follow this warning could result in personal injury or death and/or unit operation and damage.
Follow the National Electrical Code (NEC) or local codes and ordinances.
S
For personal safety, this unit MUST BE properly grounded.
S
Protective devices (fuses or circuit breakers) acceptable for unit installations are specified on the nameplate of each unit.
S
S
Do not use an extension cord with this unit.
S
Aluminum building wiring may present special problems - - consult a qualified electrician.
When unit is in STOP position, there is still voltage to electrical controls.
S
S
Disconnect power to unit before servicing by:
1. Removing power cord (if it has one) from wall receptacle.
2. Removing branch circuit fuses or turning circuit breakers off at panel.
1. Remove front panel. See Fig. 11.
2. Remove junction box.
Remove junction box cover by removing three screws from front. Remove junction box by taking
S
out top, rear and side screws. See Fig. 14.
3. Connect accessory power supply cord or hard wire connector to unit connector. See Fig. 15.
Units must be installed using the appropriate power supply kit. See Table 4 - - POWER CONNECTION
S
CHART. These connections must be followed.
4. Reinstall junction box and cover.
Use wire clamp to attach power cord to basepan. Secure with screws (included) See Fig. 16.
S
Relace junction box and cover with screws removed from Step 2. Tighten securely.
S
5. Replace front panel. See Fig. 13.
6. Connect power to unit.
Junction box cover Junction box
Fig. 14 – Junction Box Location
Fig. 16 – Wire Clamp
Unit connector
Wire clamp
Fig. 15 – Power Connection
Table 4—POWER CONNECTION CHART
CODE OF POWER SUPPLY KIT
UNIT MODEL
30A
NA*
SG-PTAC-09HDPA
PWRCORD-
SG-PTAC-12HDPA
230V-30A
SG-PTAC-15HDPA
* Using 30A on these units could result in damage to your unit.
10
Accessory
Power Supply Cord
or Hard Wire
20A
15A
230/208 VOLT
PWRCORD-
PWRCORD-
230V-30A
230V-30A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sg-ptac-12hpdaSg-ptac-15hpda

Table of Contents