Needle Replacement

Removal
1. Relieve pressure.
2. Remove air cap (1).
3. Push trigger slide (4) over to NEEDLE REMOVAL
position (D) shown on page 2.
4. Remove fluid nozzle (2).
5. Pull needle (3) out.
Installation
1. Insert needle (3).
2. Install fluid nozzle (2).
3. Push trigger slide (4) over to SPRAY position (E)
shown on page 2.
4. Install air cap.
Material
Fluid Set #2
256946
Dye
Ink
Non-Wiping Stain
Automotive Finish
Lacquer
Stain
Enamel
Epoxy
Urethane
Varnish
Primer
Industrial Finishes
Latex
Multi-Spec
Butyrate
Nitrate Dope
Oil Wall Paint
Swivel Tube Adjustment
The adjustable swivel tube allows the gun to be held in
any position while spraying.
To adjust the position of the tube in the cup:
1. Loose nut (F). Rotate cup to desired spray position.
2. Tighten nut (F).
F
ti13851a
4
Material / Fluid Set Selection Guide
Fluid Set #3
Fluid Set #4
256947
256948
ti13852a
Fluid Set #5
Fluid Set #6
256949
256950
Grooves at end of fluid needle indicate
size of fluid set. Example: Needle with 2
grooves on end goes with #2 fluid set.
Optional Artisan Air Valve (256927)
Installation
1. Remove air plug housing.
2. Install Artisan air valve.
Needle Replacement
6
3
4
ti12766a
1
2
5
Selecting Fluid Sets:
ti13753a
ti13821a
313754C