Needle Replacement; Swivel Tube Adjustment; Optional Artisan Air Valve (256927) - Graco HVLP EDGE 24Y630 Operation

Hide thumbs Also See for HVLP EDGE 24Y630:
Table of Contents

Advertisement

Needle Replacement

Needle Replacement
Removal
1. Relieve pressure.
2. Remove air cap (1).
3. Push trigger slide (4) over to NEEDLE REMOVAL
position (D) shown on page 2.
4. Remove fluid nozzle (2).
5. Pull needle (3) out.
Installation
1. Insert needle (3).
2. Install fluid nozzle (2).
3. Push trigger slide (4) over to SPRAY position (E)
shown on page 2.
4. Install air cap.
Material
Fluid Set #2
256946
Dye
Ink
Non-Wiping Stain
Automotive Finish
Lacquer
Stain
Enamel
Epoxy
Urethane
Varnish
Primer
Industrial Finishes
Latex
Multi-Spec
Butyrate
Nitrate Dope
Oil Wall Paint

Swivel Tube Adjustment

The adjustable swivel tube allows the gun to be held in
any position while spraying.
To adjust the position of the tube in the cup:
1. Loose nut (F). Rotate cup to desired spray position.
2. Tighten nut (F).
F
ti13851a
8
Material / Fluid Set Selection Guide
Fluid Set #3
Fluid Set #4
256947
256948
ti13852a
Fluid Set #5
Fluid Set #6
256949
256950
Optional Artisan Air Valve
(256927)
Installation
1. Remove air plug hous-
ing.
2. Install Artisan air valve.
6
3
4
1
2
5
Selecting Fluid Sets:
Grooves at end of fluid needle indicate
size of fluid set. Example: Needle with 2
grooves on end goes with #2 fluid set.
ti13821a
ti12766a
ti13753a
313754E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvlp edge 257827

Table of Contents