Check Electrical Grounding - Graco 244581 Instructions-Parts List Manual

Wb100 isolation system and pro xs3 spray gun b series
Hide thumbs Also See for 244581:
Table of Contents

Advertisement

Installation

Check Electrical Grounding

1. Have a qualified electrician check the electrical
grounding continuity of the spray gun and air hose.
2. Turn the ES ON/OFF valve OFF.
3. Turn off the air and fluid supply to the gun. The fluid
hose must not have any fluid in it.
4. Make sure the red-colored grounded air hose (R) is
connected and the hose ground wire is connected to
a true earth ground.
5. Using an ohmmeter (AA), measure the resistance
between the gun handle (BB) and a true earth
ground (CC). The resistance should not exceed 100
ohms. See F
. 13..
IG
6. If the resistance is greater than 100 ohms, check the
tightness of the ground connections and be sure the
air hose ground wire is connected to a true earth
ground. If the resistance is still too high, replace the
air hose.
AA
Fig. 13. Check Gun Grounding
18
I
ES
O
ti1273a
ti1259a
BB
CC
TI2161A
7. Using an ohmmeter (AA), measure the resistance
between the cabinet ground lug (214) and a true
earth ground (CC). See F
must be less than 100 ohms.
AA
Fig. 14. Check Cabinet Grounding
. 14.. The resistance
IG
214
CC
TI2163A
309293K