Download Print this page

Axis 240 User Manual page 62

Network camera server axis
Hide thumbs Also See for AXIS 240:

Advertisement

http://camserv/fullsize.jpg?clock=on&rotation=270deg
http://camserv/hugesize.jpg?camera=2&compression=high
http://camserv/fullsize.jpg?camera=3&pan=45
http://<cameraname>/cgi-bin/control?<parameter>=
<value>[&<parameter>=<value>...]
Writes the specified data string to
dataout=<string>
the Pan/Tilt serial port. Maximum
128 bytes.
Reads the specified number of bytes
from the Pan/Tilt port. The returned
read=<n>
value will be hexadecimal coded and
placed between #'s, e.g. #3A#.
Waits the specified number of
seconds before reading from the
wait=<n>
Pan/Tilt port. Used together with the
"read" parameter.
camserv
camserv
camserv
Hexadecimal coded
bytes {0, 1, 2, 3, 4, 5, 6,
7, 8, 9, A, B, C, D, E, F,
a, b, c, d, e, f}
1 ... 128
1 ... 9

Advertisement