INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CONTROL FEATURES:
3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
VERSA•TOUCH OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the
product and proper installation; therefore, before attempting to install and operate your Casablanca
fan, read this owner's manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off
at the circuit breaker or fuse box before attempting any installation procedure.
• All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualified electri-
cian should be consulted if you are unsure.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan
installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling
installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum
current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 2.8 amps or 340 watts of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
use only genuine Casablanca blades, light fixtures, and accessories.
• The blades in each pack are matched for equal
weight to assure smooth fan operation. If
more than one fan is being installed, be
careful not to mix blades from different
cartons.
• Inspect the contents of your carton for
possible shipping or handling damage and
report any such damage directly to your
authorized Casablanca dealer.
• It is always a good idea to have an assistant
to help with the installation.
• When cleaning, painting, or working near
your fan, be very careful of the fan and blades.
Always turn the power OFF to the ceiling fan
before servicing it, working on it, or replacing
light bulbs.
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged
in any way. Contact Casablanca Fan Company
by calling toll free 1-888-227-2178, or
contact your local authorized Casablanca
dealer for assistance in obtaining service.
CONTENTS
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

BEFORE YOU START

For best performance and for your warranty to be valid,

SAFE USE

(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
P/N 4243210 REV.G
FUSE BOX
BM1103
18"
70"
84"
1

Advertisement

Table of Contents
loading

Summary of Contents for Casablanca AURORA

  • Page 1: Safety First

    • This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling installations.
  • Page 2: Mounting Recommendations

    MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount- ing recommendations as you decide where to install your Casablanca fan.
  • Page 3: Installation Instructions

    If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit breaker to place your Casablanca fan, an approved ceiling fixture or fuse box), lower the old fixture and disconnect the wiring.
  • Page 4: Crossbar Mounting Bracket Installation

    ™ URORA CROSSBAR MOUNTING BRACKET INSTALLATION CEILING FAN Proceed with installation as follows: APPROVED Step 1. Route the wires from the ceiling outlet box through WIRING BOX the crossbar mounting bracket center hole. Attach the bracket, with ground wire and ridges down, to the ‘Approved For Ceil- ing Fan Installation’...
  • Page 5: Hanging The Fan

    ™ URORA HANGING THE FAN Step 3. To hang the fan body in the canopy, hold the fan body firmly and in- sert the nylon ball into the canopy opening. Check that no wires were pinched. Rotate the fan body until the slot in the nylon ball fits into the pin opposite the canopy opening.
  • Page 6: Canopy Hatch Installation

    ™ URORA CANOPY HATCH INSTALLATION Step 5. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires CANOPY are clear of the canopy opening. HATCH Step 6.
  • Page 7: Blade Installation

    ™ URORA BLADE INSTALLATION BLADE SCREW (4 PER BLADE) STEEL WASHER BLADE (4 PER BLADE) Step 9. Attach each blade to a blade holder securing it with the four steel washers and blade screws provided. Tighten securely by hand only. BLADE HOLDER BLADE/BLADE HOLDER INSTALLATION...
  • Page 8: Installing The Switch Housing

    ™ URORA COMPLETING INSTALLATION CONNECTING THE SWITCH HOUSING MODULE Step 12. For 3-Speed models only, hold the switch housing up to the fan and connect the motor plug to the switch housing socket. The connec- tor is keyed to ensure correct installation.
  • Page 9: Speed Operation

    3-SPEED OPERATION Pull-chain switches on the fan control the fan and lights. Using the fan control pull-chain switch: Fan off at start. OPTIONAL LIGHT FAN & SPEED PULL CHAIN CONTROL First pull: fan ON, low speed SWITCH PULL CHAIN SWITCH Second pull: medium speed Third pull: high speed Fourth pull: fan OFF...
  • Page 10 3-SPEED W-40 WALL CONTROL OF THE FAN • The W-40 allows the choice of four (4) different speed settings. • No light fixture is used. • Set the FAN pull chain switch to the HIGH speed setting. • No changes in household or fan wiring are required.
  • Page 11 A. Lift door SNAP PLUG proper polarity. away from control B SOCKET Replace the and remove C. battery door. Changes or modifications not expressly approved in writing by Casablanca Fan Co. may void the user’s authority to operate this equipment.
  • Page 12 VERSA•TOUCH OPERATION Fan Control SEND To start the fan. Press the selected speed button to run the fan at the desired speed. SIGNAL Low speed Medium speed High speed To turn off the fan. Press the FAN OFF button. Airflow Direction To reverse the airflow press the REVERSE button.
  • Page 13: Troubleshooting

    Never Lubricate this Fan! should be used to prevent scratching the finish. A vacuum cleaner The precision motor at the heart of your Casablanca fan features brush nozzle can remove heavier dust. Surface smudges or an accu- sealed bearings that are lubricated for life. Do not attempt to oil mulation of dirt and dust can easily be removed by using a mild the motor.
  • Page 14 PERFORMANCE AND ENERGY INFORMATION Airflow Power Use Airflow Efficiency Fan Speed (CFM)* (watts) (CFM/watt) 1533 3528 6465 *Measured according to the ENERGY STAR®-approved Solid State test method. Ceiling fan airflow is measured in cubic feet per minute (CFM). Power use is measured in watts.
  • Page 15 ’ ™ URORA WNER ANUAL 3-Speed Model Only...
  • Page 16 761 C • P , CA 91768 ORPORATE ENTER RIVE OMONA : 888-CASA-1ST (227-2178) www.CasablancaFanCo.com ©C 2003 C • U.S. P OPYRIGHT ASABLANCA OMPANY ATENT ENDING RINTED IN...