Updating Firmware On Zoned Sas Storage (Mds600, D6000, And D2600/D2700 Drive Enclosures) - HP 634041-006 Deployment Manual

Solutions with 6gb sas bl switches and external sas storage enclosures
Table of Contents

Advertisement

Updating firmware on zoned SAS storage (MDS600, D6000, and D2600/D2700
drive enclosures)
Firmware files are provided in multiple file formats for installation in different environments. When
a MDS600, D6000, or D2600/D2700 is connected to an HP 6Gb SAS BL Switch in a BladeSystem
solution, firmware must be updated using the HP Virtual SAS Manager (VSM) software utility and
one of the following firmware image file packages:
Zoned SAS storage enclosure model
MDS600 and D6000
D2600/D2700
* Smart Components are not supported for use when the MDS600 or D2600/D2700 is installed in BladeSystem
solutions.
NOTE:
Schedule a maintenance window in which you can power off all server blades with access
to the MDS600, D6000, or D2600/D2700.
Be sure the VSM switch software version is 2.0.1.0 or later.
In dual-domain configurations, if both I/O modules for an MDS600 or D6000 drawer or
D2600/D2700 enclosure are attached to a pair of SAS switches on the same BladeSystem
interconnect bay row, the VSM will attempt to update the firmware on both the primary and
secondary IO modules.
Be sure to access the HP 6Gb SAS BL Switch with the Active (or Not Redundant) VSM.
The Update Storage Enclosure Firmware task is available in the VSM interface only if the
following conditions are met: the server blades with access to the MDS600, D6000, or
D2600/D2700 have been powered off and the switch status is Active or Not Redundant.
The following is an overview of key firmware updating steps when using the VSM GUI. For detailed
information about updating MDS600, D6000, or D2600/D2700 firmware using the VSM GUI
or CLI, see the HP 6G Virtual SAS Manager User Guide.
1.
Obtain the latest MDS600, D6000, or D2600/D2700 firmware image file from the HP
Support Downloads page: http://www.hp.com/support/downloads.
2.
Power off all servers that map to the storage enclosure.
3.
From the workstation with access to both the firmware file and the BladeSystem c-Class
enclosure, access the VSM for the Active (or Not Redundant) switch.
4.
Click the refresh icon to ensure that you are viewing the most recent status information and
correct any issues before proceeding.
5.
In the VSM, select the Maintain tab, and then click Update Storage Enclosure Firmware.
6.
Expand the Reset enclosures after update drop-down box and select Yes.
7.
Click Browse and navigate to the location of the previously-obtained firmware file.
8.
Expand the Enclosure product type drop-down box and select an option.
9.
In the Storage Enclosures section, check each enclosure to update.
10. Click OK to begin the update.
The blue MDS600, D6000, or D2600/D2700 UID lights turn on to indicate the firmware is
being updated. Wait for a completion message to display.
IMPORTANT:
process may corrupt the firmware. This process may take up to 15 minutes. Wait a few minutes
for the storage enclosures to reset.
1 1. Restart the servers and resume I/O.
68
Maintenance and troubleshooting
Do not interfere with or cancel the flashing process. Interrupting the flashing
Supported firmware file package type
.fuf
.pmc

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents