3-4. Changing the Standard Setting Values (Video Level)
3-4. Changing the Standard Setting
Values (Video Level)
When changing the setting of black level, flare, gamma,
manual knee and white clip by the user's desire, perform
the procedures below.
3-4-1. Setting Status before Changing the
Setting.
. . . . . Side Panel
GAIN switch:
OUTPUT/DL/DCC +:
WHITE BAL switch:
ZEBRA switch:
HYPER GAIN switch:
SET UP switch:
EZ MODE button:
A.IRIS MODE:
ATW button:
. . . . . Front Panel
FILTER control:
SHUTTER switch:
. . . . . Lens
IRIS:
ZOOM:
3-18
LOW (0 dB)
CAM/DCC +
A
OFF
OFF
STD
OFF
STD
OFF
1 (3200 K)
OFF
M (Manual)
M (Manual)
3-4-2. Changing the Setting Value of Black
Level
Equipment:
Waveform monitor
Test point:
VIDEO OUT connector
Procedure for changing the setting
1. Set the lens iris to the close position (C).
2. Push the WHT/BLK switch in the "BLK" direction to
make a black balance.
3. SERVICE menu "PAGE 15"
M.BLACK:
4. Set the black level A with the UP
switch.
M.BLACK Standard setting value = 2070 (for NTSC)
or DOWN
2075 (for PAL)
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1