Monitored Values - Omron CJ Series Operation Manual

Sysmac temperature control units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

Data Ranges
Allocated word(s)
Loop 1: D (m+13)
Loop 2: D (m+23)
Loop 3: D (m+53)
Loop 4: D (m+63)
Loop 1: D (m+14)
Loop 2: D (m+24)
Loop 3: D (m+54)
Loop 4: D (m+64)
Loop 1: D (m+15)
Loop 2: D (m+25)
Loop 3: D (m+55)
Loop 4: D (m+65)
Loop 1: D (m+16)
Loop 2: D (m+26)
Loop 3: D (m+56)
Loop 4: D (m+66)
Loop 1: D (m+17)
Loop 2: D (m+27)
Loop 3: D (m+57)
Loop 4: D (m+67)
Note
2-6-2

Monitored Values

Allocated word
Loop 1: n+3
PV (Process Value)
Loop 2: n+4
(Indicates the present
Loop 3: n+13
temperature.)
Loop 4: n+14
Two-loop Tempera-
Heater Current Monitor
ture Control Units
only:
Loop 1: n+13
Loop 2: n+14
Loop 1: D (m+18)
Manipulated Variable
Loop 2: D (m+28)
Monitor
Loop 3: D (m+78)
(See note 1.)
Loop 4: D (m+88)
Note
50
Setting
BCD range
Control
0001 to 0099
Period
Control Sen-
0000 to 9999
sitivity
Proportional
0001 to 9999
Band
Integral Time 0000 to 9999
Derivative
0000 to 9999
Time
1. If a setting is out-of-range, the Setting Error Flag will be turned ON and the
incorrect setting will be identified by the Setting Error Number. (The incor-
rect setting will be invalid and the Temperature Control Unit will operate
with the previous setting.)
2. When a loop's Save Bit is turned ON, that loop's settings will be saved to
the Temperature Control Unit's EEPROM.
3. Do not write the settings to EEPROM more than 100,000 times.
4. The Heater Burnout Detection function will be disabled if the Heater Burn-
out Current is set to 0.0 A or 50.0 A. The HB Alarm Output will be OFF
when the HB Current is set to 0.0 A; it will be ON when the HB Current is
set to 50.0 A.
Setting
BCD range
Depend on the input type. Refer to
2-1-3 Input Specifications.
0000 to 0550
(See note 2.)
0000 to 1000
1. The Manipulated Variable Monitor indicates the manipulated variable that
is presently being output.
When ON/OFF control is being used, this value will be 100% for ON and
0% for OFF.
2. If the heater current exceeds 55.0 A, the monitor value will indicate CCCC.
Binary range
Units Default
0001 to 0063
Sec-
20
onds
°C or
0000 to 270F
0.8
°F
°C or
0001 to 270F
8.0
°F
0000 to 270F
Sec-
233
onds
0000 to 270F
Sec-
40
onds
Binary range
Units
°C or °F
0000 to 0226
A
(See note 2.)
0000 to 03E8
%
Section 2-6
Memory protection
value
The Temperature Con-
trol Unit's settings are
written to RAM. When
the Save Bit is turned
ON, the settings are
written to EEPROM.
(See notes 2 and 3.)
If DIP switch pin 8 is
ON, the settings are
automatically trans-
ferred from EEPROM
to the CPU Unit when
the power is turned
ON or the Tempera-
ture Control Unit is
restarted.
Initial
Memory
value
protection
---
---
---
---
---