120V WIRING DIAGRAM
MOTOR 2
120VAC-24VDC
TRANSFORMER
MOMENTARY
DRY CONTACT INPUTS
NOTE: ALL 4 OR 6
CONDUCTOR TELEPHONE
WIRES MUST HAVE THE
CONNECTORS ORIENTED
THE SAME ON BOTH
ENDS. DO NOT REVERSE
THE CONNECTORS AS IS
COMMONLY DONE WITH
TELEPHONE EQUIPMENT.
SEE SUPPLIED WIRE FOR
CORRECT ORIENTATION.
240V WIRING DIAGRAM
MOTOR 2
120VAC-24VDC
TRANSFORMER
MOMENTARY
DRY CONTACT INPUTS
NOTE: ALL 4 OR 6
CONDUCTOR TELEPHONE
WIRES MUST HAVE THE
CONNECTORS ORIENTED
THE SAME ON BOTH
ENDS. DO NOT REVERSE
THE CONNECTORS AS IS
COMMONLY DONE WITH
TELEPHONE EQUIPMENT.
SEE SUPPLIED WIRE FOR
CORRECT ORIENTATION.
BUS
INTERFACE UNIT
1
Up
T6
Down
Common
T6
6-BUTTON
WALL SWITCH
BUS
INTERFACE UNIT
1
Up
T6
Down
Common
T6
6-BUTTON
WALL SWITCH
T6 = 6 CONDUCTOR TELEPHONE WIRE
T4 = 4 CONDUCTOR TELEPHONE WIRE
1
= SINGLE CONDUCTOR 18 AWG MAX.
DRY CONTACT REQUIREMENTS:
1. CONTACT CLOSURE MUST BE MAINTAINED FOR AT LEAST
1 SECOND AND NOT MORE THAN 3 SECONDS.
2. A STOP COMMAND IS SENT BY SIMULTANEOUSLY
SENDING AN UP AND DOWN CONTACT CLOSURE.
MOTOR 1
T4
MOTOR 2
2 TO 1
T6 ADAPTOR
T6 = 6 CONDUCTOR TELEPHONE WIRE
T4 = 4 CONDUCTOR TELEPHONE WIRE
1
= SINGLE CONDUCTOR 18 AWG MAX.
DRY CONTACT REQUIREMENTS:
1. CONTACT CLOSURE MUST BE MAINTAINED FOR AT LEAST
1 SECOND AND NOT MORE THAN 3 SECONDS.
2. A STOP COMMAND IS SENT BY SIMULTANEOUSLY
SENDING AN UP AND DOWN CONTACT CLOSURE.
MOTOR 1
T4
MOTOR 2
2 TO 1
T6 ADAPTOR
4
RECEPTACLE FOR
MAIN POWER CONNECTION AND
24VDC TRANSFORMER PLUG IN
120VAC 60 HZ
BLACK
WHITE
EXTERNAL WIRING
GROUND
RECEPTACLE FOR
MAIN POWER CONNECTION AND
24VDC TRANSFORMER PLUG IN
240VAC 60 HZ
BROWN
BLUE
EXTERNAL WIRING
GROUND