Specifications; Fuel Consumption; Reconfiguring The Fuel System For Lp Vapor - Generac Power Systems QuietSource 005028-0 Owner's Manual

15kw/20kw/25kw liquid-cooled, prepackaged standby generators
Hide thumbs Also See for QuietSource 005028-0:
Table of Contents

Advertisement

1.11 SPECIFICATIONS

1.11.1 ENGINE
Make ......................................................................................Ford
Displacement ............................................153 inches
Cylinder Arrangement......................................................4, in-line
Valve Arrangement................................................Overhead Cam
Firing Order........................................................................1-3-4-2
Number of Main Bearings............................................................5
Compression Ratio..........................................................9.37 to 1
No. of Teeth on Crank ............................................................36-1
Ignition Timing (Waste Spark System)
at 1800 rpm (NG) ..........................................36 degrees BTDC
at 1800 rpm (LP vapor) ................................28` degrees BTDC
Spark Plug Gap ............................................................0.044 inch
Recommended Spark Plugs
Motorcraft ................................................................AWSF-52-C
Oil Pressure....................................................................30-50 psi
Crankcase Oil Capacity......................4.5 U.S. quarts (4.26 liters)
Recommended Engine Oil........................................SAE 15W-40
Type of Cooling System ..................Pressurized, closed recovery
Cooling Fan ..............................................................Pusher Type
Cooling System Capacity ......................2 U.S. gallons (7.6 liters)
Recommended Coolant ............Use a 50-50 mixture of ethylene
Home standby control board assembly part
!
number 0E9704 must be used on 1800 rpm gen-
erators.
1.11.2 GENERATOR
Model
Rated Max. Cont.
AC Power Output (kW)*
Rated Voltage (volts)
No. of Rotor Poles
Driven Speed of Rotor (rpm)
Rotor Excitation System
Type of Stator
Rotor Insulation
Stator Insulation
* Rated power of generator is subject to and limited by such factors as ambient temperature, altitude, engine condition, and other fac-
tors. Engine power will decrease about 3.5% for each 1000 feet above sea level and will decrease an additional 1% for each 10°F
above 60°F . Maximum output power of the generator is limited by maximum engine power.
3
(2.5 liters)
glycol base and deionized water.
Single-phase
005031-0
25
120/240
4
1800
Direct excited brush type
4 Wire
Class F
Class H
Section 1 — General Information
Liquid-cooled 15, 20 and 25 kW Generators

1.12 FUEL CONSUMPTION

15 kW Models
Using Natural Gas ........................................236 cu. ft. per hour
Using LP Gas ..................................................92 cu. ft. per hour
20 kW Models
Using Natural Gas ........................................307 cu. ft. per hour
Using LP Gas ................................................122 cu. ft. per hour
25 kW Models
Using Natural Gas ........................................441 cu. ft. per hour
Using LP Gas ................................................175 cu. ft. per hour
Fuel consumption is given at rated maximum con-
tinuous power output when using natural gas
rated at 1000 Btu per cubic foot; or LP gas rated
2520 Btu per cubic foot. Actual fuel consumption
obtained may vary depending on such variables as
applied load, ambient temperature, engine condi-
tions and other environmental factors.
Fuel pressure for a natural gas set up should be five
inches to 14 inches of water column (0.18 to 0.5
psi) at all load ranges.
Fuel pressure for an LP vapor set up should be 11
inches to 14 inches of water column (0.4 to 0.5
psi) at all load ranges.
1.13 RECONFIGURING THE FUEL
SYSTEM FOR LP VAPOR
All models are configured for natural gas (NG)
from the factory.
To reconfigure the fuel system from NG to LP vapor,
follow these steps:
1. Turn the main gas supply off.
Single-phase
005028-0
20
120/240
4
1800
Direct excited brush type
4 Wire
Class F
Class H
NOTE:
NOTE:
Single-phase
005030-0
15
120/240
4
1800
Direct excited brush type
4 Wire
Class F
Class H
7

Advertisement

Table of Contents
loading