Generac Power Systems Guardian 005260-1 Owner's Manual
Generac Power Systems Guardian 005260-1 Owner's Manual

Generac Power Systems Guardian 005260-1 Owner's Manual

Standby generator
Table of Contents

Advertisement

2.4L

Serial Number

35kW
Models: 005259-1
005260-1
STANDBY GENERATOR
OWNER'S MANUAL
A new standard of reliability
Not intended for use in critical life support applications.
—CAUTION—
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!
This manual should remain with the unit.
0G0238A
No.
Part
05/06
A
Rev.
Cover057

Advertisement

Table of Contents
loading

Summary of Contents for Generac Power Systems Guardian 005260-1

  • Page 1: Serial Number

    2.4L Serial Number 35kW Models: 005259-1 005260-1 STANDBY GENERATOR OWNER'S MANUAL A new standard of reliability   Not intended for use in critical life support applications. —CAUTION— ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION! DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY! This manual should remain with the unit.
  • Page 2: Table Of Contents

    SECTION SAFETY RULES ... 1-1 INTRODUCTION ...1-3 Read this Manual Thoroughly ...1-3 Operation and Maintenance ...1-3 How to Obtain Service ...1-3 IDENTIFICATION RECORD ...2-1 Data Label ...2-1 EQUIPMENT DESCRIPTION ...3-1 Equipment Description ...3-1 Engine Oil Recommendations ...3-1 Coolant Recommendations...3-1 ENGINE PROTECTIVE DEVICES ...4-1 High Coolant Temperature Switch ...4-1 Low Coolant Level Sensor ...4-1 Low Oil Pressure Switch ...4-1...
  • Page 3: Safety Rules

     SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas. Safety should be stressed to all operators, potential operators, and service and repair technicians for this equipment.  WARNING: The engine exhaust from this product contains chemicals known to the state...
  • Page 4: Fire Hazards

    • Before performing any maintenance on the gen- erator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
  • Page 5: Introduction

    INTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
  • Page 6: Identification Record

    ENGINE RPM ALTERNATOR SUBTRANSIENT REACTANCE ALTERNATOR TRANSIENT REACTANCE CLASS ROTOR GENERAC POWER SYSTEMS, INC. Standby Generator Sets General Information For actual information related to this particular model, please refer to the Manual Drawing Listing located at the end of this manual, or to the data label affixed to the unit.
  • Page 7: Equipment Description

    EQUIPMENT DESCRIPTION This equipment is a revolving field, alternating cur- rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units. See the Specifications section for exact numbers.
  • Page 8: Engine Protective Devices

    ENGINE PROTECTIVE DEVICES The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm. For that reason, the engine has several devices designed to protect it against potentially damaging conditions by automatically shutting down the unit when the oil pressure is too low, the coolant temperature is too high, the coolant...
  • Page 9: Fuel Systems

    FUEL SYSTEM FUEL REQUIREMENTS The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing Listing that is affixed to the unit includes the “Identification Code,” which may be used to identify the type of fuel system installed on the unit.
  • Page 10: Specifications

    SPECIFICATIONS GENERATOR Type ... Synchronous Rotor Insulation ... Class H Stator Insulation ... Class H Total Harmonic Distortion ...< 3.5% Telephone Interference Factor (TIF) ...< 50 Alternator Output Leads 3-phase ... 4-wire Bearings ...Sealed Ball Coupling ...Flexible Disc Load Capacity (Standby Rating) ...35kW* NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, ISO3046 and DIN 6271 Standards.
  • Page 11: Cold Weather Kit

    CONTROL PANEL GENERATOR CONNECTION CIRCUIT BREAKER Battery Charger Input 120 Volt + Neutral Ground Level STUB-UP AREA Concrete Slab See Install Dwg for Dimensions COLD WEATHER KIT For cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: •...
  • Page 12: General Information

    GENERATOR AC LEAD CONNECTIONS See “Voltage Codes”. This generator may be rated at any one of three voltages, either single-phase or three-phase. The electrical wires in the unit’s AC con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
  • Page 13: Installation

    INSTALLATION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. PREPARATION BEFORE START-UP The instructions in this section assume that the standby generator has been properly installed, ser- viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor. Be sure to read the “Safety Rules”, as well as all other safety information in this manual, before attempting to operate this (and related) equipment.
  • Page 14: Start-Up Checklist

    START-UP CHECKLIST  Before working on the generator, ensure the fol- lowing: • The AUTO/OFF/MANUAL switch is in the OFF position. • The 120VAC supply to the battery charger is switched OFF . PREPARATION FOR START-UP • Ensure that the 120VAC circuit breaker to the bat- tery charger is open.
  • Page 15: Operation

    GENERATOR CONTROL AND OPERATION Refer to the appropriate control panel operator’s manual for this unit. OPERATING UNIT WITH MANUAL TRANSFER SWITCH If the generator was installed in conjunction with a transfer switch capable of manual operation only, the following procedure applies. A manually operated transfer switch is one that will not provide automatic start-up and does not include an intelligence circuit.
  • Page 16: Maintenance

    MAINTENANCE PERFORMED BY AUTHORIZED SERVICE FACILITIES  Before working on the generator, ensure the fol- lowing: • The AUTO/OFF/MANUAL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120VAC supply to the battery charger is switched OFF .
  • Page 17: Battery Fluid

    Figure 10.1 - Oil Dipstick and Oil Fill Cap Oil Fill Cap BATTERY FLUID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low, add dis- tilled water to cover tops of separators. DO NOT USE TAP WATER IN BATTERY.
  • Page 18: Changing Engine Oil

    CHANGING ENGINE OIL Refer to maintenance performed by authorized service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning. This means warm up the engine, shut it down and drain immediately as follows: 1.
  • Page 19: Miscellaneous Maintenance

    MISCELLANEOUS MAINTENANCE CLEANING THE GENERATOR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. Periodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dry, low pressure air to remove any accumulations of dirt.
  • Page 20: Service Schedule

    SERVICE SCHEDULE 30 KW - 150 KW STANDBY GAS ENGINE DRIVEN GENERATOR SETS The following is a recommended maintenance schedule for standby gas engine driven generator sets from 30kW to 150 kW in size. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
  • Page 21 Maintenance Level 1 Tasks Recom- mended Comp. to be done Comp. to be done to be done (Date- monthly/ Initials) 10 hrs. 1. Disable the unit from operating per the first page warning. 2. Check the engine oil level. Adjust as necessary.
  • Page 22 Maintenance Level 1 Tasks Recom- mended Comp. to be done Comp. to be done to be done (Date- monthly/ Initials) 10 hrs. 10. Check the engine accessory drive belts and fan coupling device if equipped for correct tension, wear, weather cracking, and damage.
  • Page 23 Maintenance Level 1 Tasks Recom- mended Comp. to be done Comp. to be done to be done (Date- monthly/ Initials) 10 hrs. 18. Start and exercise the unit at full rated load (use a load bank if the site load is not enough) for at least 2 hours looking for leaks,...
  • Page 24: Troubleshooting

    TROUBLESHOOTING GUIDE PROBLEM CAUSE Engine won’t crank. Engine cranks but won't start Engine starts hard, runs rough. Engine starts then shuts down. AUTO/OFF/MANUAL Switch at OFF, engine continues to run No AC output from generator. *Contact the nearest Authorized Dealer for assistance. Standby Generator Sets Troubleshooting 1.
  • Page 25 Standby Generator Sets Notes...
  • Page 26 Standby Generator Sets Notes...
  • Page 27 Standby Generator Sets Notes...
  • Page 29 0F3137 PAN CB CONN BOX 0F3188 STAND RH CONTROL 0F3189 STAND LH CONTROL 023484N BUSHING SNAP SB-2.5-31 (3) 5 0F6366B 1 / 2 XFMR DUAL 120V/16V (FOR 120/240V & 277/480V UNITS) 0F6366A XFMR DUAL 104V/16V (FOR 120/208V UNITS) (3) 6 043180 2 / 4 WASHER FLAT M4...
  • Page 31 UL CIRCUIT BREAKER (QJ-2P) 0F8137 COVER QJ 2P FRM CB 065469 DECAL, DANGER HIGH VOLTAGE 0E7994 CB 0225A 240V 2P S QJ22 0F8136 COVER QJ 2P CB DISH 036261 RIVET POP .125 X .275 SS 022473 WASHER FLAT 1/4-M6 ZINC 022097 WASHER LOCK M6-1/4 022127...
  • Page 33 0G0056 RTR-2390--35KD1 CPL 0G1155 RTR-2390--35KD1 CPL (G2) 0F9677 RTR-2390--45KD1 CPL 0G0959 RTR-2390--45KD1 CPL (G2) 0G0057 STR-2390--35AD1 CPL 0F9664 STR 390 45K 2P 1PH DIRECT 0G0058 STR-2390--35KD1 CPL 0G0184 STR 390 45KW 2P 3PH 480V 0G0059 STR-2390--35GD1 CPL 0G0183 STR 390 45KW 2P 3PH 208V 0C9708 INSTR HYPOT TEST (NOT SHOWN) SEE ENGINE EV...
  • Page 35 COMPONENTS INCLUDED IN 0F9696E 0F1823A ENCL HSB CONTROL PANEL 0F3078 COVER CONTROL PANEL 0F2606 HINGE CONTINUOUS H-PANEL 036261 RIVET POP .125 X .275 SS 043181 SCREW PHM M3-0.5 X 10MM 052777 WASHER FLAT M3 0F8710B ASSY PCB CPL2 CTRLR 3600 RPM 0F1262 HOLDER, FUSE WICKMANN 178.6150 0F1263...
  • Page 37 COMPONENTS INCLUDED IN 0G1290E 0F1823A ENCL HSB CONTROL PANEL 0F3078 COVER CONTROL PANEL 0F2606 HINGE CONTINUOUS H-PANEL 036261 RIVET POP .125 X .275 SS 043181 SCREW PHM M3-0.5 X 10MM 052777 WASHER FLAT M3 0G1303B ASSY PCB CPL2A CTRLR 3600 RPM 0F1262 HOLDER, FUSE WICKMANN 178.6150 0F1263...
  • Page 39 0F9517 WELDMENT FRAME 2.4L C2 052860 NUT FLANGED HEX M12-1.75 052251 DAMPENER VIBRATION 40 BLUE 052257 SPACER .49 X .62 X 1.87 PWDR/ZNC 052252 DAMPENER VIBRATION 052259 WASHER FLAT M12 052891 SCREW HHC M12-1.75 X 80 G8.8 0536210410 ASSY WIRE 14.00" 042909 SCREW HHC M8-1.25 X 30 G8.8 047411...
  • Page 41 0F3408B BATTERY TRAY C1 CPL 0F3411 STRAP BATTERY RETAINMENT 025507 WASHER SHAKEPROOF EXT 7/16 STL 052212 SCREW HHC M10-1.25 X 25 G8.8 046526 WASHER LOCK M10 022131 WASHER FLAT 3/8-M10 ZINC 050331A BATTERY POST COVER RED + 050331 BATTERY POST COVER BLACK - 038805Y CABLE BATTERY BLACK #1 X 18.00 03880400AE...
  • Page 43 0E6586 GASKET BOSCH 32 & 40 0E0519A ADAPTER CARBURETOR W/PVC CONN 0C8127 ELEMENT AIR CLEANER 052619 SCREW HHC M5-0.8 X 20 G8.8 022127 NUT HEX 1/4-20 STEEL 062974 STUD TH 1/4-20 X 4-1/2 G2 ZNC 0G0190 PLATE, AIR CLEANER TOP 2.4L 037561 NUT WING 1/4-20 NYLK 022097...
  • Page 45 0G1008 ENGINE 2.4L G2 (REWORK) 046526 7 (REF) WASHER LOCK M10 039414 4 (REF) SCREW HHC M8-1.25 X 35 G8.8 0G0149 1 (REF) SCREW SHC M14-1.5 X 35 G10.9 0E9868A 1 (REF) ALTERNATOR DC W/OUT PULLEY 0F3217 1 (REF) SPACER DC ALTERNATOR PULLEY 042574 1 (REF) ADAPTOR 1/8NPTF TO 1/8BSPT...
  • Page 47 0F9529 WELDMENT RADIATOR SUPPORT 2.4L 0F2608 RADIATOR 598 X 568 X 49 CPL RH 0F5263 V-BELT 31/64" X 57-3/8" 046526 WASHER LOCK M10 059981 SCREW HHC M10-1.5 X 30 G10.9 022222 SCREW HHC 5/16-24 X 1-1/2 G5 0F5050 SHIELD RADIATOR C5 042568 SCREW HHC M6-1.0 X 20 G8.8 0F2573...
  • Page 49 026915 NIPPLE CLOSE 3/4 X 1.375 075580 FLANGE FUEL INLET 0F6390B REGULATOR ASSY 2.4L 039253 SCREW HHC M8-1.25 X 20 G8.8 022145 WASHER FLAT 5/16-M8 ZINC 022129 WASHER LOCK M8-5/16 045771 NUT HEX M8-1.25 G8 CLEAR ZINC 040173 CLAMP HOSE #5.5 .62-.62 0E8286 STREET EL 45D 1/2 NPT BRASS 026812...
  • Page 51 0G0045 (XX) REAR WRAP C2 CPL 0C2454 SCREW THF M6-1 X 16 N WA Z/JS 0F5849 (XX) DOOR C2 087233 RIVET POP .1875 X .450 SS 0E3257 SCREW TH-FRM M6 W/CAP SHKPRF W 0F5852 (XX) DISCHARGE DUCT LH & RH SIDE C2 0F9833 (XX) FRONT CORNERS C2 0F5851 (XX)
  • Page 53 0F9794 MUFFLER 7" X 9" X 18-1/2" 2" IN/OUT 0G0113 EXHAUST ELBOW 2 1/4 OD 2 1/2OD 0G1007 BRACKET MUFFLER 0F2830 MUFFLER BRACKET STIFFENER 0F2962 MUFFLER STRAP 080762 BOLT U 3/8-16 X 2.62 0E0170A EXHAUST BLANKET 988MM (C2) 0C2454 SCREW THF M6-1 X 16 N WA Z/JS 0G0776 PIPE EXHAUST G2 0G0007...
  • Page 67 C2 UNITS 0F9832 SHIELD CONN BOX C2 0F9832GGS0R SHIELD CONTROL STAND C2 0C2454 SCREW THF M6-1 X 16 N WA Z/JS C3 UNITS 0F9832B SHIELD CONTROL STAND C3 0F9832KGS0R SHIELD CONTROL STAND C3 0C2454 SCREW THF M6-1 X 16 N WA Z/JS C4 UNITS 0F9832A SHIELD CONTROL STAND C4...
  • Page 68 • A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a Non - Generac Power Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the genset, no warranty coverage shall apply.

This manual is also suitable for:

Quietsource 005259-1

Table of Contents