This manual contains pertinent owner’s information, including warranty, electrical diagrams, exploded views, and lists of repair parts for generator model number 004614-1. In addition, the latter portion of this manual contains information necessary for the proper installation of these generators.
Many accidents are caused by failing to follow simple and fundamental rules or precautions. Generac cannot possibly anticipate every possible cir cumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit, are, therefore, not all-inclusive.
Inspect the unit’s fuel system fre- quently and correct any leaks immediately. Before placing this equipment into service, the fuel supply lines must be properly installed, purged, and leak- tested according to applicable fuel-gas codes. Generac Safety Rules Power Systems, Inc. ®...
1. Model Number ____________________ 3. kW Rating__________________________ Generac Power Systems, Inc. ® 2. Serial Number __________________ 4. Rated Voltage __________________ Model: 004614-1 QUIETPACT™ 65D 1. 2-Pole, 30-amp Circuit Breaker 2. Hourmeter 3. Oil Fill Opening and Plug 4. Oil Dipstick 5.
Also, appropriate care should be taken in applica- tions where extremely low ambient temperatures are possible, to ensure the temperature of the diesel fuel is not allowed to fall below levels where “gelling” could occur. Generac NOTE: Power Systems, Inc. ®...
1.5.2 FUEL CONSUMPTION (GAL/HR) Model No Load QUIETPACT™ 65D 0.28 (004614-1) 1.5.3 ENGINE OIL REQUIREMENTS Use a high-quality detergent oil with American Petroleum Institute (API) classification “For Service CC.” Detergent oils keep the engine cleaner and reduce carbon deposits. Use oil having the following SAE vis-...
2.3.1 INSTALLATION Generator installation must have been properly com- pleted so that it complies with all applicable codes, standards, and regulations and with the manufactur- er's recommendations. Generac NOTE: NOTE: Power Systems, Inc. ®...
Close windows, doors, and other openings in the vehicle that, if open, might permit exhaust gases to enter the vehicle. Generac Power Systems, Inc. ® The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This...
This normally-open (N.O.) thermostatic switch has a sensing tip that is immersed in captive coolant. Should the coolant temperature exceed approximate- ly 115° C (240° F), the switch contacts close, and the engine shuts down automatically. Generac Power Systems, Inc. ®...
2.8.2 25-HOUR CHECK-UP After the 25-hour break-in period, contact a Generac Authorized Service Dealer for the following mainte- nance, for which the vehicle owner is responsible for all charges: •...
8. Screw the new filter on by hand, until its gasket lightly contacts the oil filter adapter. Then, tight- en the filter an additional 3/4 to one turn. Generac OIL DIPSTICK (PANEL TRANSPARENT FOR VIEWING PURPOSES.
See the “Service Schedule,” Section 3.13 (Page 16), for recommended air cleaner maintenance. SPARK ARRESTOR MUFFLER The exhaust muffler supplied with the QUIETPACT™ 65D is a spark arrestor type. Generac exhaust muf- flers for recreational vehicle generators do not have a 12 Generac Power Systems, Inc.
Once each year, have the generator cleaned and inspected by a Generac Authorized Service Dealer. Service technicians will use dry, low-pressure air to clean internal windings. Parts inside the control con- sole should be cleaned and inspected at this time, as well.
Generac Authorized Service Dealer. 3.11 EXERCISING THE GENERATOR Generac recommends that you start and operate the generator at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine. If you cannot exercise the generator every seven days, and it is to be out of service longer than 30 days, see Section 3.12.
7. Apply electrical loads to at least 50 percent of the unit’s rated wattage capacity. 8. When the engine is thoroughly warmed up, shut it down. 9. Your generator is now ready for service. Section 3 – Maintenance QUIETPACT™ 65D Recreational Vehicle Generator Generac Power Systems, Inc. 15 ®...
Section 3 – Maintenance QUIETPACT™ 65D Recreational Vehicle Generator 3.13 SERVICE SCHEDULE ATTENTION: It is recommended that all service work be performed by your nearest Generac Authorized Service Dealer. SYSTEM/COMPONENT X = Action R = Replace/Adjust as Needed * = To Be Completed by a Generac Authorized Service Dealer.
(a) use of common hand tools, (b) use of special Generac tools, and (c) use of any tools and/or equipment from other suppliers. Generac cannot possibly know of, nor advise the...
Page 21
There must be no possibility of fuel vapors enter- ing the vehicle interior. • You are required to install an approved, flexible, nonconductive fuel line between the generator fuel connection point and the rigid fuel lines. Generac Safety Rules Power Systems, Inc. 19 ®...
Boulevard, Rexdale, Ontario, Canada, M9W 1R3. EQUIPMENT DESCRIPTION Instructions and information in this section pertain to Generac liquid-cooled generators, designed specifically for installing in recreational vehicles. The QUIET- PACT™ 65D operates 230-volt, single-phase, 50-Hertz, AC electrical loads that require up to 28.2 amps at 230 volts.
Page 23
Section 1 – General Information QUIETPACT™ 65D Recreational Vehicle Generator Major Features and Dimensions — Drawing No. D2650-A Figure 1.2 – Major Features and Dimensions Generac Power Systems, Inc. 21 ®...
The fol- lowing general rules apply: • Vehicle construction MUST be capable of support- ing the weight of the generator. 22 Generac Power Systems, Inc. ® • Whether the generator is mounted above the hori- zontal support tubing or suspended below the tub- ing, the supporting frame used must be structural- ly sound.
• If the compartment is lined with galvanized steel, it may be constructed of any material. Generac rec- ommends that the compartment be constructed of 1/2-inch thick plywood (not strandboard), with the...
One excellent insulating material is a 1- inch (25 mm) thick fiberglass having a 2-pound den- sity. When fiberglass is used, its coated side should face toward the compartment interior. 24 Generac Power Systems, Inc. ® Do not install sound insulation or any absorbent material on the compartment floor interior.
• Generator cooling air inlet and front service door • Four holes for passage of generator mounting bolts. See Section 2.1.4 (Page 23) • Rear service door. Fuel lines and exhaust piping must not pene- trate into the vehicle living area. Generac Power Systems, Inc. 25 ®...
187.5 square inches (1,218.75 cm QUIETPACT™ 65D Recreational Vehicle Generator 2.3.4 TESTING THE INSTALLATION Generac recommends testing the installation to be sure adequate cooling airflow is available to the unit, before placing the unit into service. If the unit shows signs of overheating, you will need to enlarge the air openings.
If the generator is to share the vehicle’s engine tank, separate fuel pickup tubes are required for the engine and the generator. Generac recommends that you make the fuel pickup tube 2 to 3 inches (51 to 76 mm) shorter than the vehicle’s engine pickup tube.
• Use enough exhaust system hangers to prevent any part of the system from being dislocated. • Use exhaust system parts recommended by Generac. Using unapproved exhaust mufflers and exhaust system parts is the responsibility of the person(s) installing such unauthorized parts.
Flexible metal conduit is NOT vapor-tight along its entire length. 30 Generac Power Systems, Inc. ® • From the junction box, route power supply wires...
NOTE: If the battery is to be used to power other vehicle accessories, as well as to start the generator, you may need a battery with a larger capacity. 32 Generac Power Systems, Inc. ® 2.7.2 BATTERY CABLES Using battery cables that are too long or too small in diameter may cause a drop in voltage, which causes starting problems.
Installation of such a panel will per- mit you to start and stop the generator engine from any convenient location inside the vehicle. Figure 2.20 – Remote Panel Plug-in Receptacle Generac WIRE #18 (STOP) WIRE #150 (PREHEAT)
The generator engine is equipped with a high coolant temperature switch. The switch has normal- ly open (N.O.) contacts. When the engine coolant temperature is too high, switch contacts close, and the engine shuts down automatically. GENERAC RECOMMENDS THAT YOU TEST THE GENERATOR FOR ADEQUATE COOLING.
❑ Check that remote start/stop panels (if used) are installed properly. ❑ Check that all other options and accessories (if used) are installed properly. POST INSTALLATION TESTS ❑ Check that all tests are completed properly. ____________________________________________________ ______________________________________________________ ________________________________________________ CHECKS Generac Power Systems, Inc. 35 ®...
2. Check cooling system for leaks. 3. Disconnect Remote Harness Check/Replace Start/Stop Switch 4. Replace pressure switch. 5. Replace temperature switch. 6. Contact a Generac Authorized Service Dealer 7. Replace control board. 1. Replace switch. 2. Reconnect or close wire.
Appendix 3 — Exploded Views and Parts Lists QUIETPACT™ 65D Recreational Vehicle Generator Engine, Alternator Drive and Starter Assembly – Drawing No. 0D5057-A 40 Generac Power Systems, Inc. ®...
Page 43
¼" SPECIAL LOCK WASHER M8 FLANGE NUT TAPTITE, M6-1.0 X 8MM ENGINE, 1.0L DIESEL WASHER, FLAT M12 CLAMP, VINYL COATED, ¾" HHCS M12-1.25 X 25MM TENSIONER, SE-F18-4.5" ½"-13 X1-3/4" HHCS ½"-13 FLANGE NUT FLAT WASHER, 5/16" Generac Power Systems, Inc. 41 ®...
Page 44
0C6722 PLATE, CLEANOUT 042907 HHCS M8-1.25 X 16 022129 WASHER, SPLIT LK- M8 022097 WASHER, SPLIT LK -1/4-M6 42 Generac Power Systems, Inc. ® ITEM PART NO. QTY. DESCRIPTION 043146 HHCS M6-1.00 X 10 0C7561 CARRIAGE BOLT 3/8 -16 X 55MM...
Page 45
DECAL, MAX HOT / MIN COOLANT DECAL, WARNING RV SUPPORT, COOLANT TANK NUT, HEX M6-1.0 FOAM, AIR DUCT FACE FOAM, AIR DUCT SIDE DECAL, UNIT WASHER, SPLIT LOCK ¼" - M6 DECAL, ENGINE DATA DECAL, CSA APPROVAL Generac Power Systems, Inc. 43 ®...
Page 46
Appendix 3 — Exploded Views and Parts Lists QUIETPACT™ 65D Recreational Vehicle Generator Cooling System – Drawing No. D2360 44 Generac Power Systems, Inc. ®...
Page 47
Hose 5/16" SAE-20R4 Clamp, Vinyl Coated 1-5/8" Cap, Radiator Pressure Clamp, Vinyl Coated 1-1/16" Gasket, Radiator Base Clamp, Vinyl Coated 1-½" Nut, Hex M8-1.25 Bracket, Support ½"-13 x 1-¾" HHCS Tensioner ½"-13 Flange Nut Generac Power Systems, Inc. 45 ®...
Page 48
WASHER, FLAT M5 0D2021B HARNESS 0C3992 M4-0.7 X 16 HHCS TAPTITE 0C7022 DECAL, CUSTOMER CONNECTION 46 Generac Power Systems, Inc. ® 25 26 ITEM PART NO. QTY. A/R = AS REQUIRED * NOT SHOWN REFER TO WIRING DIAGRAM C4946 DESCRIPTION...
Page 49
0C5105 022145 039253 043107 035586 042909 042907 022145 0709390357 075673 Generac DESCRIPTION WASHER, SPLIT LK -M8 NUT, HEX M8-1.25 CRIMPTITE, ¼"-20 X 5/8" BRACKET, SUPPORT WASHER, FLAT - M8 HHCS M8-1.25 X 20 HHCS M8-1.25 X 25 HOSE CLAMP #20 HHCS M8-1.25 X 30...
Page 50
047411 HHCS M6-1.00 x 16 0C7968 Hex Nut 3/8-16 Brass 022237 Washer Split Lk 3/8 075763 Boot, Battery Cable 48 Generac Power Systems, Inc. ® ITEM PART NO. QTY. DESCRIPTION 075763A Boot, Battery Cable 0C7413 Grommet 3/8 I/D x 1 GD 022127 Hex Nut ¼...
Page 51
HOSE CLAMP SIZE #16 M4-0.7 X 16 HHCS TAPTITE WASHER, FLAT #6 GROMMET GASKET, ENGINE CONTROL BOX CIRCUIT BREAKER, 30A, 2 POLE NUT, HEX M6-1.0 PHMS M5-0.8 X 12 FLATWASHER, #8 WASHER, SPLIT LOCK 1/4”-M6 Generac Power Systems, Inc. 49 ®...
Page 53
0709390119 0709390120 0709390121 0709390131 0709390123 0709390124 0709390125 0709390126 0709390127 0709390128 0709390129 0709390130 MM = MILLIMETER U.S. = UNDERSIZE Generac DESCRIPTION DOWEL PIN SPRING PIN STUD STUD STUD SNAP RING OIL SEAL DRAIN COCK CONNECTOR OIL FILTER TAPPET PUSH ROD RELIEF VALVE O-RING Power Systems, Inc.
Page 54
VALVE GUIDE SEAL (INTAKE) 0709390154 SPRING 0709390155 RETAINER 0709390156 0709390157 0709390158 CYLINDER HEAD GASKET, 1.2MM THICK 0709390159 CYLINDER HEAD GASKET, 1.3MM THICK 52 Generac Power Systems, Inc. ® ITEM PART NO. QTY. DESCRIPTION 0709390160 BOLT 0709390161 BOLT 0709390162 LIFTING EYE 0709390163 BOLT...
Page 55
070939-223 070939-224 070939-225 070939-230 070939-231 U.S. - UNDERSIZE O.S. - OVERSIZE AR - AS REQUIRED MM - MILLIMETER Generac DESCRIPTION STANDARD PISTON RING SET PISTON RING SET-0.5MM O.S. PISTON RING SET-1.0MM O.S. PISTON PIN SNAP RING CONNECTING ROD ASSEMBLY BUSHING...
Page 56
THRUST WASHER 0709390253 ROTOR 0709390254 OIL PUMP COVER 0709390255 0.10MM SHIM 0709390532 0.15MM SHIM 0709390533 0.20MM SHIM 0709390258 0.50MM SHIM 54 Generac Power Systems, Inc. ® ITEM PART NO. QTY. DESCRIPTION 0709390259 SPRING 0709390260 COLLAR 0709390261 SNAP RING 0709390262 FRONT PLATE...
Page 57
Appendix 3 — Exploded Views and Parts Lists QUIETPACT™ 65D Recreational Vehicle Generator 1.0 Liter Diesel Rocker Arm Assembly – Drawing No. 075683-A ITEM PART NO. QTY. 070939-176 070939-177 070939-178 070939-179 070939-180 070939-181 DESCRIPTION ROCKER ARM SHAFT SPRING SCREW SPRING,PIN STUD Generac Power Systems, Inc. 55 ®...
GENERAC and ISM recommend that you retain the original purchase documentation and all receipts covering maintenance on your engine, but GENERAC and ISM cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
GENERAC. Add-on or modified parts may not be used for maintenance or war- ranty repairs. Such use will be grounds for disallowing a warranty claim, and GENERAC will not be liable to warrant fail- ures of warranted parts caused by the use of an add-on or modified part.
NOTE: ALL UNITS MUST BE INSTALLED BY GENERAC POWER SYSTEMS AUTHORIZED SERVICE FACILITIES. For a period of 3 (three) years or 2,000 (two thousand) hours of operation from the date of original sale, whichever occurs first, Generac Power Systems, Inc. (Generac) will, at its option, repair or replace any part which, upon examination, inspection, and testing by Generac or a Generac Authorized Warranty Service Facility, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below.
Need help?
Do you have a question about the 004614-1 and is the answer not in the manual?
Questions and answers