Comparing RAID Levels
Use this table to select the RAID levels that are most appropriate for the logical drives on your storage
space, based on the number of available disk drives and your requirements for performance and reliability.
RAID Level
Redundancy
RAID 0
No
RAID 1
Yes
RAID 1E
Yes
RAID 10
Yes
RAID 5
Yes
RAID 5EE
Yes
RAID 50
Yes
RAID 6
Yes
RAID 60
Yes
Disk drive usage, read performance, and write performance depend on the number of drives in the
logical drive. In general, the more drives, the better the performance.
Proprietary and Confidential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide
Disk Drive
Read
Performance
Usage
100%
***
50%
**
50%
**
50%
**
67 – 94%
***
50 – 88%
***
67 – 94%
***
50 – 88%
**
50 – 88%
**
Write
Built-in Hot
Performance
Spare
***
No
**
No
**
No
**
No
*
No
*
Yes
*
No
*
No
*
No
Minimum
Disk Drives
2
2
3
4
3
4
6
4
8
81