A P P E N D I X B Connector And Cable Specifications; Serial Port - Cisco 1240 Hardware Installation Manual

Connected grid router
Table of Contents

Advertisement

Appendix B
Connector and Cable Specifications
Table B-4
Pin
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1. Rate Select is an optional SFP input that controls receiver bandwidth when used with Fibre Channel applications. This pin is

Serial Port

For detailed information about the combination ports, see the
Table B-5
Serial Port Specification
1
RS-232
Pin
Signal Description (Abbreviation)
1
DCE ready, ring indicator (DSR/RI)
2
Received line signal detector (DCD)
3
DTE ready (DTR)
4
Signal ground (COM)
5
Received data (RxD)
6
Transmitted data (TxD)
7
Clear to send (CTS)
8
Request to send (RTS)
1. The RS232 pinouts use the EIA-561 standard.
OL-26223-04
SFP Port Specification (continued)
Signal Name
Input/Output
MOD-DEF(0)
Output
1
Rate Select
LOS
Output
VeeR
VeeR
VeeR
RD-
Output
RD+
Output
VeeR
VccR
VccT
VeeT
TD+
Input
TD-
Input
VeeT
unconnected.
DCE
Output
Output
Input
Output
Input
Output
Input
Signal Description
Grounded in SFP, indicates SFP is present
Loss of Receive optical signal indicator
GND
GND
GND
Differential electrical output to PHY
Differential electrical output to PHY
Gnd
3.3V
3.3V
GND
Differential input from PHY
Differential input from PHY
GND
"Router Hardware Description"
RS-485 Full Duplex
Signal
Dir
TX+
TX-
Not used
COM
Not used
Output
RX+
Input
Not used
Output
RX-
Input
Cisco 1240 Connected Grid Router Hardware Installation Guide
Connector Specifications
chapter.
RS-485 Half Duplex
Signal
Dir
TX/RX+
TX/RX-
Not used
COM
Not used
Bidirectional
Not used
Not used
Bidirectional
Not used