23 Waiting time for repeated emergency call
An emergency call is repeated to check the arrival of staff until it is
acknowledged by pressing the Action button on the Carephone 62, or the
repeated call is disabled by the monitoring centre. The emergency call is
repeated when the defined waiting time is exceeded.
Enter a time between 0 and 99 minutes. 0 = off. Default value is 0.
24 Confirmation with call
When the repeated emergency call has been locally acknowledged, you can
speak directly to the monitoring centre.
0 = off (no call is made), 1 = a call is made to the monitoring centre.
Default value is 0.
25 Radio transmission monitoring
The Carephone 62 can monitor the wireless transmitters that are assigned.
The wireless transmitters send a signal to the Carephone 62 at regular
intervals. A failure message is sent to the monitoring centre if the
Carephone 62 does not receive this signal at least once a week.
0 = off, 1 = on. Default value is 0.
26 Call back waiting time
The call back function enables the help provider or monitoring centre to
terminate an alarm after having acknowledged it. The Carephone must be
called back, or the Action button must be pressed, after an alarm has been
acknowledged. Define the waiting time after the acknowledgement, during
which a call back will be accepted. If this call back waiting time has
elapsed, then a new call will be sent by the Carephone.
Enter a time between 0 and 9 minutes. 0 = off. Default value is 0.
27 Presence marking - Service done
The presence marking function allows staff members to mark their
presence or signal that the service is done by pressing the daily button.
This is handled without a speak/listen connection and does not require an
answer by the operator. When the presence marking is activated, the
destination numbers to be called are set in the call sequence of step 58.
This function resets the activity monitor, which must be set. See step 40.
0 = off, 1 = on. Default value is 0.