Target
0x00:
Modify Session S0 inventoried flag.
0x01:
Modify Session S1 inventoried flag.
0x02:
Modify Session S2 inventoried flag.
0x03:
Modify Session S3 inventoried flag.
0x04:
Modify SL flag.
Remove Select Record Index
Index of the select record to be removed from the list. This value is taken when remove select record
command is given from the main page.
RD PWR A0
Antenna power for read operation.
18
252
19
231
20
210
21
189
22
168
23
147
24
126
25
105
26
84
27
63
28
42
29
21
30
0
WR PWR A
Antenna power for write operation. Above table used for conversion.