30
5.
Place the fuse holder close to the battery. Ensure that it is not near any hot engine
component. Mount the fuse holder using its mounting hole and dress the wires as required.
6.
Insert the stripped end of the red lead of the fuse holder into the ring lug hole and crimp it.
Connect the fuse holder red adapter lead plug to the mating receptacle on the red lead of the
power cable.
7.
Connect the red lead ring lug from the fuse holder to the positive (+) battery terminal. Make
sure the adapter cable is connected to the main power cable red lead.
8.
Carefully check that all connections are proper. Insert the fuse into the fuse holder and close
the cover.
MTM5400 Mobile Terminal Installation Manual
Adapter
Red Lead
Black Lead
2
(min. 2.5 mm
)
Figure 2 Power Cable Assembly
Fuse
(10 A)
Fuse Holder
Red Lead
2
(min. 2.5 mm
)
Mounting Hole
To Battery -
or Chassis
Cover
Red Lead
2
(min. 2.5 mm
)
Ring Lugs
To Battery +