Toshiba R410A Service Manual page 118

Super heat recovery multi system
Hide thumbs Also See for R410A:
Table of Contents

Advertisement

Check code
Main
Outdoor 7-segment display
remote
controller
display
Auxiliary code
F01
F02
F03
F04
F04
F05
F05
F06
F06
F07
F07
F08
F08
F10
F12
F12
01: Comp. 1 side
F13
F13
02: Comp. 2 side
F15
F15
F16
F16
F23
F23
F24
F24
F29
F31
F31
01: Comp. 1 side
H01
H01
02: Comp. 2 side
01: Comp. 1 side
H02
H02
02: Comp. 2 side
01: Comp. 1 side
H03
H03
02: Comp. 2 side
H04
H04
H06
H06
H07
H07
01: TK1 sensor error
02: TK2 sensor error
H08
H08
03: TK3 sensor error
04: TK4 sensor error
H14
H14
01: TK1 oil circuit system error
02: TK2 oil circuit system error
H16
H16
03: TK3 oil circuit system error
04: TK4 oil circuit system error
L03
L04
L04
L05
L06
L06 No. of indoor units with priority
L07
L08
L08
L09
L10
L10
L17
L17
L18
L18
L20
L20
L28
L28
01: IPDU1 error
02: IPDU2 error
03: IPDU3 error
L29
L29
04: Fan IPDU error
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
L30
L30 Detected indoor address
L31
Wireless remote controller
Sensor block display
of receiving unit
AI-NET central
control display
Timer Ready
Operation
¤ ¤
0F
¤ ¤
0d
¤ ¤
93
¤ ¤
19
¤ ¤
A1
¤ ¤
18
¤ ¤
18
¤ ¤
1b
¤ ¤
OC
¤ ¤
A2
¤ ¤
43
¤ ¤
18
¤ ¤
43
¤ ¤
43
¤ ¤
43
¤ ¤
12
¤ ¤
1C
¤
l
IF
¤
l
1d
¤
l
17
¤
l
44
¤
l
20
l
¤
d7
¤
l
d4
¤
l
44
¤
l
d7
¤
¤
l
96
¤
¤
¡
96
¤
l
¤
96
¤
¤
l
96
¤
¤
l
99
¤
¤
l
99
¤
¤
l
46
¤
¤
¡
88
¤
¤
¡
46
¤ ¤ ¤
8A
¤
¤
¡
98
¤
¤
¡
46
¤
¤
¡
CF
¤
¤
¡
b6
118
Check code name
Flash
l
ALT Indoor TCJ sensor error
l
ALT Indoor TC2 sensor error
l
ALT Indoor TC1 sensor error
¡
ALT TD1 sensor error
¡
ALT TD2 sensor error
¡
ALT TE1 sensor error
¡
ALT TL sensor error
¡
ALT TO sensor error
l
ALT Indoor TA sensor error
¡
ALT TS1 sensor error
¡
ALT TH sensor error
¡
ALT Outdoor temp. sensor miscabling (TE, TL)
¡
ALT Outdoor pressure sensor miscabling (Pd, Ps)
¡
ALT Ps sensor error
¡
ALT Pd sensor error
l
SIM Indoor other error
¡
SIM Indoor EEPROM error
l
Compressor break down
Magnet switch error
l
Overcurrent relay operation
Compressor trouble (lock)
l
Current detect circuit system error
l
Comp 1 case thermo operation
l
Low pressure protective operation
l
Oil level down detective protection
l
Oil level detective temp sensor error
l
Comp 2 case thermo operation
Oil level detective circuit error
l
Magnet switch error
Overcurrent relay operation
SIM Indoor center unit duplicated
SIM Outdoor line address duplicated
Duplicated indoor units with priority
SIM
(Displayed in indoor unit with priority)
SIM Duplicated indoor units with priority
(Displayed in unit other than indoor unit with priority)
SIM Group line in individual indoor unit
SIM Indoor group/Address unset
SIM Indoor capacity unset
SIM Outdoor capacity unset
SIM Inconsistency error of outdoor units
SIM FS unit error
SIM Duplicated central control addresses
SIM Over No. of connected outdoor units
SIM No. of IPDU error
SIM Indoor outside interlock
Extended I/C error
Detecting device
Indoor
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
I/F
I/F
I/F
I/F
Indoor
I/F
IPDU
MG-SW
Overcurrent relay
IPDU
IPDU
I/F
I/F
I/F
I/F
I/F
I/F
MG-SW
Overcurrent relay
Indoor
I/F
I/F
I/F
Indoor
Indoor, I/F
Indoor
I/F
I/F
FS unit
AI-NET, Indoor
I/F
I/F
Indoor
I/F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents