Closed defect summary
Read-only (RO) privileges for storage encryption configuration
enables the user to remove a smart card entry.
A user without Storage Encryption configuration privileges is
able to add targets.
DCFM 10.1.3 fixes
Table 5
lists defects closed in the DCFM 10.1.3 release.
Table 5 DCFM 10.1.3 closed defects
Closed defect summary
Email notifications are not generated for triggered events in DCFM 10.1.2
or earlier, resulting in delayed notification of changes in the DCFM server.
The properties dialog is blank for an HBA with virtual tag connected to a
switch configured as an Access Gateway, and the HBA is not displayed
in the topology.
From the topology view, if you right-click and then select the Accept
Changes option, any switches selected for removal are removed, but any
devices selected for removal are not removed.
When a copy of online database is saved from one fabric and then
nl
activated in another fabric, DCFM activates the zone set on the wrong
fabric.
The LSAN Zoning Activation Dialog function removes TI zones present in
the fabric.
nl
Symptom—TI zones are missing after activating an LSAN zone.
After migrating from DCFM 10.0.2, the call home status is displayed as
disabled in the Advanced Call Home (ACH) dialog for M-EOS switches,
even though it is enabled in the Element Manager.
The user cannot disable Virtual Fabrics (VF) after all logical switches have
been deleted.
An Encryption Group that was created on an HP StorageWorks DC04
SAN Director without an HP StorageWorks DC Switch encryption blade
resident in the chassis remains after a delete operation. Multiple delete
commands are required to delete the Encryption Group.
Using the Switch tab of the New Logical Fabric Template dialog to set a
name fails to set the name to the switch.
DCFM inappropriately allows a user to activate a new configuration or
to edit the active configuration if the default zone is set to all access without
an active zone configuration. However, Prohibit Dynamic Connectivity
Mask (PDCM) will work only when there is an active zone configuration
in the fabric. When the user tries to activate a new configuration or to
edit the active configuration, it should be allowed only when there is an
active zone configuration.
HP StorageWorks B-series Data Center Fabric Manager Enterprise
Solution
Fixed in DCFM 10.1.2
Fixed in DCFM 10.1.2
Solution
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3