Hp storageworks b-series data center fabric manager enterprise 10.1.4 release notes (5697-0085, july 2009 - includes all 10.1.x
Hide thumbs Also See for Brocade 8/12c:

Advertisement

Closed defect summary
Exporting aliases not converting {D,P} member into
WWN as specified in the FS.
Symptom—When the user export the alias with {D,P}
member, the {D,P} member appears as it was in the
Zoning dialog and no conversion to the switch port
WWN occurs as specified in the FS.
Need to include runtime library config for pcsc in
DCFM script.
Server supportsave does not capture the client
logs when the client is launched through browser from
the same machine.
Symptom—When the DCFM client is launched through
the browser from the same machine, the server
support save fails to capture the client logs.
Wave Length column in port optics dialog is currently
blank.
Symptom—User does not view any value for the Wave
Length column in port optics dialog.
Port selection button does not get enabled for inactive
FCIP tunnel in performance port picker
Symptom—Suppose a tunnel is present which was
active some time back and later becomes inactive then
the user will not be able generate graph for inactive
tunnel as the port selector is disabled for inactive FCIP
tunnels in the performance port picker.
Zoning report showing zone name twice when zone
is part of active zone config.
Symptom—When user generates report with active
zone config, the active zone appears twice in the
Report with Active=Yes and Active=No values.
DCFM Professional, disable backup,
nl
migrate to enterprise, open options-backup, close, in-
valid error message.
Symptom—A confusing error message when using the
options dialog after migration. Even though the backup
is disabled the path is invalid and must contain a valid
path.
Solution
Fixed in DCFM 10.1.0
Workaround—change {D,P} entries to the
corresponding switch port WWN manually in the
exported CSV file.
Fixed in DCFM 10.1.0
Workaround—In order for smartcard to work, the
customer must edit the DCFM script to include:
# MMA STARTED
PCSC_LIB=/opt/pcsc/lib/libpcsclite.so
if [ -f $PCSC_LIB ]; then
JAVA_OPTS="$JAVA_OPTS
-Dsun.security.smartcardio.library=
$PCSC_LIB"
fi
# MMA STOP
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—If the user wants to generate the graph
for all the types[active and inactive
tunnels], the user will have to select FCIP from the
historical wizard from the "From" drop-down list and
then generate a graph. But for real time the user
cannot select in active tunnels.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—Enter a valid backup directory, even if
backup is disabled.
HP StorageWorks B-series Data Center Fabric Manager Enterprise
15