Closed defect summary
The Port Optics dialog does not display information for nondefault logical
switches.
DCFM incorrectly allows assigning port numbers higher than 32 on a 48-
port blade to a logical switch if the 256 area limit is set with a port-based
area assignment. It also allows setting the 256 area limit if the logical
switch already has ports higher than 31.
Changes made in the client export port are not effective after a client restart
in DCFM 10.1.2. or earlier.
Zeroize Encryption Engine (EE) is not supported on an HP StorageWorks
DC04 SAN Director.
After a storage array is created, the connection between the storage array
and the switch is not displayed in the topology view.
DCFM is unable to recognize a smartcard reader on a local client on
Linux or Solaris hosts because the Libpcsclite.so file is not included
in the DCFM installation.
If an incorrect KeyID is entered for key vault masterkey restore using
keyvault, the error message references an incorrect keyvault rather than
the SKM keyvault.
Web Linker crashes when Top Talkers is enabled for the Brocade 200E
in DCFM.
nl
Symptom—Some of the switch processes are terminated and switch per-
formance is reduced.
DCFM 10.1.4 fixes
Table 6
lists defects closed in the DCFM 10.1.4 release.
Table 6 DCFM 10.1.4 closed defects
Closed defect summary
When historical performance data collection is enabled, DCFM can
nl
experience slower response times. This is due to an increase in the number
of performance records in the database, and can eventually cause the
disk to run out of space.
All zoning transactions using DCFM are aborted on a virtual fabric.
However, the same zoning transactions are processed successfully using
the CLI.
FTP-related operations from the internal FTP server fail.
In an FCR/FCIP configuration, the LSAN soning dialog box does not dis-
play edge fabrics if the FID is set to 1.
36
Solution
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
nl
DCFM now prevents the user from
adding port numbers higher than
31 to a logical switch configured
for the 256 area limit with port-
based area assignment.
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
nl
Workaround—You can use the
CLI to perform Zeroize EE on the
Brocade DCX-4S.
Fixed in DCFM 10.1.3
nl
Workaround—Exit the client and
then re-launch it.
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Fixed in DCFM 10.1.3
Solution
Fixed in DCFM 10.1.4
Fixed in DCFM 10.1.4
Fixed in DCFM 10.1.4
Fixed in DCFM 10.1.4