Download Print this page

HP Brocade 8/12c Release Note page 19

Hp storageworks b-series data center fabric manager enterprise 10.1.4 release notes (5697-0085, july 2009 - includes all 10.1.x
Hide thumbs Also See for Brocade 8/12c:

Advertisement

Closed defect summary
Device Connectivity:Linux -3 of the results display
nl
"Index 0".
Symptom—Three of the results displayed in the results
dialog have "Index 0" displayed. The checks were for
Device port check and Zone configuration.
Tape Volume Label is not being displayed for tape
LUNs in DCFM.
Symptom—Tape Volume Label column does not
display any data.
DCFM causing many issues when a fabric is managed
with a large zone DB.
Symptom—When a user launches the Zoning dialog
for a large zone DB (1MB), the dialog takes a long
time and many zoning operations fail in the Zoning
dialogue.
Importing invalid zone DB xml file from Zoning dialog
not showing validation error.
Symptom—When a user imports an invalid xml file,
no warning message appears from the Zoning dialog
and nothing is imported to repository.
WebTools fails to launch for a switch running FOS
V6.1.1.
Symptom—Trying to launch WebTools page for a
switch running FOS 6.1.1 may fail after a successful
first launch.
Device Connectivity: Only LSAN check is done for
certain ports added through "Add detached".
Symptom—The result dialog shows the LSAN check
only—-no other checks are performed.
There is no warning message displayed when trying
to close an unsaved PDCM configuration.
Symptom—When a user has one or more unsaved
configurations, and he clicks 'Close', the PDCM dialog
closes without warning that the uncommitted changes
will be lost.
Config names edit WWN does not change WWN
but adds an unnamed WWN.
Symptom—Changing a name assignment by editing
the WWN in the Configure-Names dialog does not
work. It will leave the original Name - WWN pair in
the dialog and will add an unnamed WWN to the All
WWNs table.
Solution
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—Manage large zone DB from fabric
using CLI.
Fixed in DCFM 10.1.0
Workaround—Verify and validate zone DB xml file
manually before importing to offline repository.
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Fixed in DCFM 10.1.0
Workaround—First, remove this name. Then if it is an
already discovered WWN you wish to name, find it
in the All WWNs list, and then edit the Name field.
If it is an undiscovered device, then add the Name
and WWN as a detached WWN.
HP StorageWorks B-series Data Center Fabric Manager Enterprise
19

Advertisement

loading

This manual is also suitable for:

Brocade bladesystem 4/24Storageworks dcfm 10.1.0