Snmp Trap Registration - HP Brocade 8/12c Release Note

Hp storageworks b-series data center fabric manager enterprise 10.1.4 release notes (5697-0085, july 2009 - includes all 10.1.x
Hide thumbs Also See for Brocade 8/12c:

Advertisement

Deleting Logical Switches with GigE ports causes errors
When deleting a Logical Switch that has Gigabit Ethernet ports without first moving the GigE ports
to the default Logical Switch, an error message may be displayed and the delete fails.
Blank graph displayed for FCIP tunnels
When FCIP tunnels are selected from the Picker dialog in the Historical Graph, the tunnels will initially
appear as blank until the Apply button in the dialog is clicked.
Domain port index and port WWNs unavailable in Add Member dialog
The port index and port WWNs are grayed out when using the Add Member dialog. The port index
can still be selected by choosing the appropriate devices in the device tree and then moving them to
the right.
Event-based file actions fail
DCFM event actions fails to run scripts on Windows remote-mounted filesystems.
EX_Port disabled when configuring Routing Domain IDs
After selecting an edge fabric and launching the routing domain IDs dialog, if you select all of the
front domains and Xlate domains and then add appropriate domain IDs, clicking OK disables the
EX_Ports with the following message:
EX_PORT ISOLATE
E_Port information missing in EOS edge switch
When opening a graph of an E_Port to EX_Port connection, the E_Port labels are blank but the data
graphed is corrected.
Access Gateways connected to M-EOS switches not discovered
Access Gateways connected to M-EOS fabrics are not discovered by DCFM. Only Access Gateways
attached to FOS-based switches are currently able to be discovered.
Incorrect title of Top Talkers dialog
When the Top Talkers dialog is selected, the title incorrectly displays as "Realtime Port Selector."
WWNs not shown in Fabric Binding dialog
After two FOS fabrics in interop mode 0 are merged, the member's WWN is missing and the Fabric
Binding Status is listed as Unknown in the Fabric Binding dialog.

SNMP trap registration

If the discovery status displays the message Not registered for SNMP Trap, manually add
the server IP entry in the SNMP trap registration table from the switch CLI using the following command:
snmpconfig --set snmpv3
HP StorageWorks B-series Data Center Fabric Manager Enterprise
9