Configuring Errored Symbol Event Detection; Configuring Errored Frame Event Detection - HP 6125XLG Configuration Manual

Blade switch high availability configuration guide
Table of Contents

Advertisement

Configuring errored symbol event detection

An errored symbol event occurs when the number of detected symbol errors in the detection window
(specified number of received symbols) exceeds the predefined threshold.
You can configure this command in system view or interface view. The configuration in system view takes
effect on all ports, and the configuration in interface view takes effect on the specified port. For a port,
the configuration in interface view takes precedence.
To configure errored symbol event detection globally:
Step
1.
Enter system view.
2.
Configure the errored symbol
event detection window.
3.
Configure the errored symbol
event triggering threshold.
To configure errored symbol event detection on a port:
Step
1.
Enter system view.
2.
Enter Ethernet interface view.
3.
Configure the errored symbol
event detection window.
4.
Configure the errored symbol
event triggering threshold.

Configuring errored frame event detection

An errored frame event occurs when the number of times that error frames in the detection window
(specified detection interval) are detected exceeds the predefined threshold.
You can configure this command in system view or interface view. The configuration in system view takes
effect on all ports, and the configuration in interface view takes effect on the specified port. For a port,
the configuration in interface view takes precedence.
To configure errored frame event detection globally:
Step
1.
Enter system view.
2.
Configure the errored frame
event detection window.
3.
Configure the errored frame
event triggering threshold.
Command
system-view
oam global errored-symbol-period
window window-value
oam global errored-symbol-period
threshold threshold-value
Command
system-view
interface interface-type
interface-number
oam errored-symbol-period
window window-value
oam errored-symbol-period
threshold threshold-value
Command
system-view
oam global errored-frame window
window-value
oam global errored-frame
threshold threshold-value
6
Remarks
N/A
By default, the errored symbol
event detection window is
100000000.
By default, the errored symbol
event triggering threshold is 1.
Remarks
N/A
N/A
By default, an interface uses the
value configured globally.
By default, an interface uses the
value configured globally.
Remarks
N/A
By default, the errored frame event
detection window is 1000
milliseconds.
By default, the errored frame event
triggering threshold is 1.

Advertisement