Conditional Registers
The fault Condition Register and the Status Condition Register are read only registers
that the user may read to see the condition of the supply. Refer to Table 8-8 for
description of the Fault Condition Register bits and Table 8-9 for the Status Condition
register bits.
BIT
Fault name
0 (LSB)
Spare bit
1
AC Fail
2
Over
temperature
3
Foldback
4
Over voltage
5
Shut Off
6
Output Off
7(MSB)
Enable
BIT
Fault name
0 (LSB)
Constant
Voltage
1
Constant
Current
2
No Fault
3
Fault active
4
Auto-Restart
Enabled
5
Fold
Enabled
6
Spare bit
7(MSB)
Local Mode
8.11.2. Service Request: Enable and Event Registers
The conditional Registers are continuously monitored. When a change is detected in a
register bit, which is enabled, the power supply will generate an SRQ message.
The SRQ message is: "Inn" terminated by CR, where the nn is the power supply address.
The SRQ will be generated either in Local or Remote mode.
Refer to Tables 8-10 to 8-13 for details of the Enable and Event registers.
Table 8-10: Fault Condition Register (FLT?)
Fault symbol
Bit Set condition
SPARE
Fixed to zero
AC
AC fail has occurred.
OTP
OTP shutdown has
occurred.
FOLD
Foldback shutdown has
occurred
OVP
OVP shutdown has
occurred.
SO
Rear panel J1 "Shut Off"
condition has occurred.
OFF
Front panel OUT button
pressed to Off.
ENA
Rear panel J1 Enable
terminal (J1-1&J1-14)
opened.
Table 8-11: Status Condition Register (STAT?)
Fault symbol
Bit Set condition
CV
Output is On and the
supply in CV.
CC
Output is ON and the
supply in CC.
The power supply is
NFLT
operating normally or
fault reporting is not
enabled.
See "OUT n" command
in Section 8.7.5.
FLT
One or more faults are
enabled and occur.
AST
Supply is in Auto-Restart
mode (from Front Panel
or serial command).
FDE
Fold protection
enabled (from Front
Panel or serial
command).
SPARE
Fixed to zero.
LCL
Supply in Local mode.
83-530-000 Rev J
Bit Reset condition
Fixed to zero
The AC input returns to normal.
The power supply cools down.
The supply output is turned On by
front panel button or OUT 1 command.
The supply output is turned ON by
front panel button or OUT 1 command.
Rear panel J1 "Shut Off" condition
removed.
The supply output is turned On by
front panel button or OUT 1 command.
Rear panel J1 Enable terminals
closed.
Bit Reset condition
Output is ON and the supply is not in
CV.
Output is ON and the supply is not in
CC.
One or more faults are active and fault
reporting is enabled (using "FENAxx").
Fault Event Register cleared (FEVE?).
Supply is in Safe-Start mode (from
Front Panel or serial command).
Fold protection disabled (from Front
Panel or serial command).
Fixed to zero.
Supply in Remote mode or Local-
Lockout mode.
82

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesys 10kwGenesys 15kw

Table of Contents