TDK Genesys User Manual page 68

10kw/15kw programmable dc power supplies
Table of Contents

Advertisement

6.4.4.
To Release From Slave Mode
Slave units can be released using the following procedure:
a)
Depress FINE button for 3 seconds. The current display changes to show the
master or slave setting.
b)
Select "H1" mode using the CURRENT encoder.
c)
Depress FINE button again or wait 5 seconds.
d)
Turn the AC power Off and On to store the new setting.
e)
The front panel will be locked. Unlock it by depressing the PREView button until the
display shows "UFP".
f)
After exiting from Slave operation the unit's parameters will be set to:
 Programmed Voltage to zero
 Programmed Current to zero
 UVL to zero volts
 OVP to its maximum value
83-530-000 Rev J
 AST OFF
 OUT OFF
 Foldback protection OFF
 Locked Front Panel
64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesys 10kwGenesys 15kw

Table of Contents