Number
Control/Indicator
1
VOLTAGE control
2
VOLTAGE indicator
3
VOLTAGE display
4
CURRENT display
5
CURRENT indicator
6
CURRENT control
7
OUT button
8
OUT indicator
9
REM/LOC button
10
REM/LOC indicator
11
FOLD button
12
FOLD indicator
Table 4-1: Front Panel Controls and Indicators
Description
High resolution rotary encoder for adjusting the Output Voltage. Also
adjusts the OVP/UVL levels and selects the Address
Green LED, lights for constant-Voltage mode operation.
4 digit, 7-segment LED display. Normally displays the output voltage.
When the PREV button is pressed, the display indicates the
programmed setting of the output voltage. When the OVP/UVL button
is pressed, the Voltage display indicates the OVP/UVL setting.
4 digit, 7 segment LED display. Normally displays the output current.
When the PREV button is pressed, the display indicates the
programmed setting of output current.
Green LED, lights for Constant-Current mode operation
High resolution rotary encoder for adjusting the Output Current. Also
selects the Baud-Rate of the communication port.
Main function: Output ON/OFF control. Press OUT to set the output
On or Off. Press to reset and turn On the output after OVP or FOLD
alarm events have occurred.
Auxiliary function: Selects between "Safe-Start" and "Auto-Restart"
modes. Press and hold OUT button to toggle between "Safe-Start"
and "Auto-Restart". The VOLT display will cycle between "SAF" and
"AUT". Releasing the OUT button while one of the modes is
displayed, selects that mode.
Green LED, lights when the DC output is enabled.
Main function: Go to local. Press REM/LOC to put the unit into Local
(REM/LOC button is disabled at Local Lockout mode).
Auxiliary function: Address and Baud Rate setting. Press and hold
REM/LOC for 3 sec. to set the Address with the VOLTAGE encoder
and the Baud Rate with the CURRENT encoder.
Green LED, lights when the unit is in Remote mode.
Foldback protection control.
-Press FOLD to set Foldback protection to On.
-To release Foldback alarm even, press OUT to enable the output
and re-arm the protection.
-Press FOLD again to cancel the Foldback protection.
Green LED, lights when Foldback protection is On.
83-530-000 Rev J
42
Section
5.2.1
5.3.1
5.4.1
8.2.2
5.2.2
8.2.4
5.6
5.11
8.2.5
8.2.2
8.2.4
5.5