TDK Genesys User Manual page 80

10kw/15kw programmable dc power supplies
Table of Contents

Advertisement

#
Command
22
UVL?
23
AST n
24
AST?
25
SAV
26
RCL
27
MODE?
28
MS?
NOTES:
1.
In Advance parallel mode (refer to Sec. 6.2.1), "n" is the total system current.
2.
In Advanced parallel mode, "MC?" returns the Master unit current multiplied by the number
of slave units +1.
Description
Returns the setting "n" where "n" is the exact string in the user's "UVL n". When in Local
mode, returns the last setting from the front panel in a 4 digit string.
Sets the Auto-restart mode to ON or OFF.
AST 1 (or AST ON): Auto restart On.
AST 0 (or AST OFF): Auto restart Off.
Returns the string auto-restart mode status.
Saves present settings. The settings are the same as power-down last setting. These
settings are erased when the supply power is switched Off and the new "last settings" are
saved.
Recalls last settings. Settings are from the last power-down or from the last "SAV"
command.
Returns the power supply operation mode. When the power supply is On (OUT 1) it will
return "CV" or "CC". When the power supply is OFF (OUT 0 or fault shutdown) it will
return "OFF".
Returns the Master/Slave setting. Master: n= 1, 2, 3, or 4 Slave: n=0
83-530-000 Rev J