Advertisement

Table 4-2: Rear Panel Connections and Controls
Number
Item
1
AC input connector
2
DC output
3
Remote-In
connector
4
Remote Out
connector
5
J1 Analog Remote
connector
6
SW1 Setup switch
7
J2 Remote sense
connector
8
Blank or Option
Plate
9
IEEE switch LAN
switch
10
Ground screw
Description
M6 Stud terminal suitable for ring lugs.
Bus-bars up to 300V models.
Stud terminals for models above 300V.
RJ-45 type connector, use for connecting power supplies to RS232
or RS485 port of computer for remote control purposes. When using
several power supplies in a power system, the first unit Remote-In is
connected to the computer and the remaining units are chained,
Remote-In to Remote-Out.
RJ-45 type connector, used for chaining power supplies to form a
serial communication bus.
Connector for remote analog interface. Includes output voltage and
current limit programming and monitoring signals, Shut-off control
(electrical signal), Enable/Disable control (dry-contact), power
supply ok (PS_OK) signal and operation mode (CV/CC) signal.
Nine position DIP switch for selecting remote programming and
monitoring modes for Output Voltage, Current Limit and other
control functions.
Connector for making remote sensing connections to the load for
regulation of the load voltage and compensation of load wire drop.
Blank sub-plate for standard units.
Other plates and connectors for options such as Isolated Analog,
IEMD or LAN.
Two position DIP switch for selecting option mode or RS232/485
mode. The options may be IEEE or LAN.
M5x20mm screw for chassis ground connection.
45
83-530-000 Rev J
Section
3.7
Fig. 4.2
8.3
8.4
8.3
8.4
4.4
4.3

Hide quick links: