No mounting hardware used

1.
Use the M3 screws provided with the tape drive in the screw pack labeled 'General Mounting
Screws'. Check that the holes in the chassis are aligned with the holes in the sides of the drive
and use a regular Phillips screwdriver to secure the M3 screws, as shown in
If you cannot tighten the screws, use the washers provided in the pack.
1. M3 screws, supplied with tape drive
Figure 22 Securing drive, no mounting hardware used
.
2.
Ensure blanking plates are in place over empty bays and replace the cover on the server.

Reboot the server

Reboot the server to power up the tape drive and server.
Watch the boot screen carefully after installation. If there are any error or unexpected messages go
back and check the SAS cabling carefully.
Have you installed the SAS cable correctly?
Have you reconnected all devices securely?
If this does not resolve the problem, refer to "Troubleshooting" on page 61 for further guidelines.
36
Installing an internal Ultrium tape drive
Figure 22
on page 36.