Hitachi C 10FSH Handling Instructions Manual page 10

Slide compound miter saw
Table of Contents

Advertisement

7. Check the lower limit position of the Saw Blade.
Although it was adjusted before shipment, carefully check the height of the saw blade.
Confirm that the saw blade can be lowered 10mm to 11mm (13/32" to 7/16") below the
table insert. For details, see the section on "Checking the saw blade lower limit position".
8. Check the Power Receptacle.
To prevent overheating, accidental stopping or intermittent operation, confirm that the
power cord plug fits properly in the electrical receptacle and does not fall out after it is
inserted. Repair or replace the receptacle if it is faulty.
9. Confirm the tool's power cord is not damaged.
Repair or replace the power cord if an inspection indicates that it is damaged.
AFTER CONNECTING THE POWER PLUG TO AN APPROPRIATE AC POWER
SOURCE, CHECK THE OPERATION OF THE TOOL AS FOLLOWS:
10. Trial Run
After confirming that no one is standing behind, the power tool start and confirm that
no operating abnormalities exist before attempting a cutting operation.
11. Inspect the rotating stability of the saw blade.
For precise cutting, rotate the saw blade and check for deflection to confirm that the
blade is not noticeably unstable; otherwise vibrations might occur and cause an accident.
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents