Console displays "E2" error
code
No speed/RPM reading,
Console displays "E3" error
code
Console shuts off (enters
sleep mode) while in use
36
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Check data cable integrity
Check data cable
connections/orientation
Check magnet position
(requires shroud removal)
Check RPM Sensor (re-
quires shroud removal)
Check data cable integrity
Check data cable
connections/orientation
Reset Machine
Check magnet position
(requires shroud removal)
Check RPM Sensor
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
If tests reveal no other issues, Console
should be replaced.
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Magnet should be in place on pulley.
RPM sensor should be aligned with
magnet and connected to data cable.
Realign sensor if necessary. Replace if
there is any damage to the sensor or
the connecting wire.
All wires in the cable should be intact. If
any are cut or crimped, replace cable.
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Unplug unit from electrical outlet for 3
minutes. Reconnect to outlet.
Magnet should be in place on pulley.
Contact Customer Care for further