88
en | Setting up VCA
12.2

VCA - Profiles

Two profiles can be set up with different VCA configurations.
1.
2.
To rename a profile:
1.
2.
The current alarm status is displayed for information purposes.
12.2.1

Aggregation time [s]

Set an aggregation time of between 0 and 20 seconds. The
aggregation time always starts when an alarm event occurs. It
extends the alarm event by the value set. This prevents alarm
events that occur in quick succession from triggering several
alarms and successive events in a rapid sequence. No further
alarm is triggered during the aggregation time.
The post-alarm time set for alarm recordings only starts once
the aggregation time has expired.
12.2.2

Analysis type

Select the required analysis algorithm. Motion+ offers a motion
detector and essential recognition of tampering.
Metadata is always created for a video content analysis, unless
this is explicitly excluded. Depending on the analysis type
selected and the relevant configuration, additional information
overlays the video image in the preview window next to the
parameter settings. With the Motion+ analysis type, for
example, the sensor fields in which motion is recorded are
marked with rectangles.
AM18-Q0635 | v5.6 | 2013.01
In the VCA configuration drop-down list, select profile 1 or
2 and enter the required settings.
If necessary, click Default to return all settings of the
selected profile to its default values.
To rename the file, click the icon to the right of the list field
and enter the new profile name in the field.
Click the icon again. The new profile name is saved.
Software manual